Translate this page into:
Determination of copper, nickel, manganese and cadmium ions in aqueous samples by flame atomic absorption spectrometry after simultaneous coprecipitation with Co(OH)2
⁎Corresponding author. shamspur@gmail.com (Tayebeh Shamspur)
-
Received: ,
Accepted: ,
This article was originally published by Elsevier and was migrated to Scientific Scholar after the change of Publisher.
Peer review under responsibility of King Saud University.
Abstract
A separation-preconcentration procedure was developed for the determination of trace amounts of copper, nickel, manganese and cadmium ions in water samples by flame atomic absorption spectrometry after coprecipitation by Co(OH)2 as a carrier without a chelating agent. The influence of the various analytical parameters such as pH, amount of carrier reagent, standing time, centrifugation rate and time, sample volume and matrix effects on the recovery of the analyte ions was studied. Under the specified experimental conditions the calibration curves for Ni(II) and Cu(II) were linear from 0.5 to 200 ng mL−1 and for Mn(II) and Cd(II) from 0.5 to 250 and 0.3 to 80 ng mL−1, respectively. The relative standard deviations for seven replicate determinations of a mixture of 40.0 ng mL−1 of Cu(II), Ni(II), Mn(II) and 20 ng mL−1 of Cd(II) in the original solution were 1.9%, 1.7%, 1.8% and 2.1%, respectively. The detection limits based on 3Sb/m for Cu(II), Ni(II), Mn(II) and Cd(II) in the original solution were 0.2, 0.2, 0.3 and 0.07 ng mL−1, respectively. The limits of quantification based on 10Sb/m for Cu(II), Ni(II), Mn(II) and Cd(II) in the original solution were 6.7, 6.7, 10.0 and 2.3 ng mL−1, respectively. The proposed method has been applied to the determination of trace amounts of the analyte ions in two certified reference materials (the National Institute for Environment Studies (NIES) No. 1 Pepperbush and NIES No. 7 Tea Leaves) and water samples and satisfactory results were obtained.
Keywords
Multielement determination
Coprecipitation
Preconcentration
1 Introduction
The monitoring of the levels of heavy metal ions in environmental samples is an important part of analytical chemistry due to their positive or negative influences on the human body (Hedberg et al., 2011; Mohammadi et al., 2011; Tobiasz et al., 2012). Some metals such as manganese and copper are essential micronutrients and have a variety of biochemical functions in all living organisms. While these elements are essential, they can be toxic when taken in excess (Ensafi and Shiraz, 2008; Hedberg et al., 2011; Mohammadi et al., 2013a). However, some metals such as cadmium are non-essential metals as they are toxic, even in traces (Ensafi and Shiraz, 2008; Hajiaghababaei et al., 2013; Hedberg et al., 2011).
Atomic absorption spectrometer (AAS) is generally main instrument of analytical chemistry laboratories for the determination of traces heavy metal ions, due to its relatively low cost. However the main two problems for the determination of heavy metal ions by AAS are low levels of metal ions and interferic influences of main components of samples (Hassanien and Abou-El-Sherbini, 2006; Mohammadi et al., 2013b). In order to solve these important problems, various preconcentration/separation methods including liquid liquid extraction (Lemos et al., 2012; Mirzaei et al., 2011), hydride generation (Miravet et al., 2004), cloud point extraction (Mohammadi et al., 2013b), dispersive liquid liquid microextraction (Mohammadi et al., 2016) and solid phase extraction (Dadfarnia et al., 2007; Mohammadi et al., 2010; Sabermahani et al., 2013; Yacoub et al., 2013; Afzali et al., 2012a,b) were used. However, these procedures are labor intensive, time and reagent consuming, and require large volume of sample.
Coprecipitation is also one of the efficient separation/preconcentration techniques for traces of heavy metal ions (Bulut et al., 2010; Saracoglu et al., 2006; Tuzen and Soylak, 2009; Zhang et al., 2004). The coprecipitation technique has some advantages: simple, fast method and several analyte ions can be preconcentrated and separated from the matrix simultaneously. In the coprecipitation procedure, a precipitate is formed by combination of a carrier element and a suitable inorganic or organic ligand (Divrikli and Elci, 2002). Various carrier elements including copper, nickel, aluminum, erbium, magnesium, indium, and samarium have been used (Bulut et al., 2010; Divrikli and Elci, 2002; Doner and Ege, 2005; Saracoglu et al., 2006; Soylak and Tuzen, 2008; Zhang et al., 2004; Uluozlu et al., 2009, 2010).
Titanium and zirconium, molybdenum and their oxides, were separated by coprecipitation with cobalt (II) hydroxide for a final determination by X-ray fluorescence spectrometry (Wurzinger and Muller, 1977). In this study, a separation/preconcentration procedure using Co2+ for coprecipitation of copper, nickel, manganese and cadmium ions has been developed prior to flame atomic absorption spectrometry (FAAS) determination. The most important advantage of the proposed method include absence of the need for any chelating agent, simplicity, low cost, enhancement of sensitivity, rapid analysis time and high enrichment factor.
2 Materials and methods
2.1 Instrumentation
A SensAA GBC atomic absorption spectrometer (Dandenong, Australia) equipped with deuterium background correction and air–acetylene burner was used for absorbance measurements. Copper, nickel, manganese and cadmium hollow cathode lamps were used as light source at wavelengths of 324.8, 232.0, 279.5 and 228.8 nm, respectively. The instrumental parameters are listed in Table 1. The acetylene flow rate and burner height were adjusted in order to obtain the maximum absorbance signal, while aspirating the analyte solution. A Metrohm 692 pH meter (Herisau, Switzerland) was used for pH measurements. A Centurion scientific centrifuge model 1020 D.E. (West Sussex, United Kingdom) was used to accelerate the phase separation.
| Analyte ion | Wavelength (nm) | Slit width (nm) | Lamp current (mA) | Optimum working range of instrument (μg/mL) |
|---|---|---|---|---|
| Cu(II) | 324.7 | 0.5 | 4.0 | 0.03–10 |
| Ni(II) | 232.0 | 0.2 | 4.0 | 0.1–20 |
| Mn(II) | 279.5 | 0.2 | 5.0 | 0.02–5 |
| Cd(II) | 228.8 | 0.5 | 4.0 | 0.02–3 |
2.2 Reagents and solutions
Deionized water was used throughout the experimental work. Standard solutions of copper (0.5–200.0 ng mL−1), nickel (0.5–200.0 ng mL−1), manganese (0.5–250.0 ng mL−1) and cadmium (0.3–80.0 ng mL−1) were prepared by diluting stock solutions of 1000.0 mg L−1 of these ions supplied by Merck (Darmstadt, Germany). The working reference solutions were prepared daily by stepwise dilution from stock solutions with deionized water. For preparation of blank solution 50 mL distilled water was given and the pH was adjusted to 11 by NaOH solution. The laboratory glassware was soaked overnight in a 1.4 mol L−1 HNO3 solution. Before using, all of the glasswares were washed with deionized water and dried. Solutions of alkali metal salts (1% w/v) and various metal nitrate and acetate salts (0.1% w/v) were used to study the interference of anions and cations, respectively. HNO3 and NaOH solutions were used for pH adjustments.
2.3 Coprecipitation procedure
The coprecipitation procedure was optimized with 50 mL of an aqueous solution containing 5.0 ng mL−1 of Cu(II), Ni(II), Mn(II) and 1.0 ng mL−1 of Cd(II) prior to its application to the real samples. First, the pH of solution was adjusted to 11.0 by NaOH solution. Then 1.25 mL of 1000 mg L−1 of Co(II) was poured into the centrifuge tube. After 10 min, the mixture was centrifuged at 4000 rpm for 5 min. The supernatant was removed and the precipitate was dissolved with 2.0 mL of 4 mol L−1 HNO3. The final solution was aspirated directly into the FAAS for determination of the analyte ions.
2.4 Preparation of real samples
Two certified reference materials (CRMs) supplied by the National Institute for Environment Studies (NIES) No. 1 Pepperbush and NIES No. 7 Tea Leaves have been analyzed. Approximately 0.5 g of NIES No. 1 and 1.0 g of NIES No. 7 were weighted accurately into two Teflon cup (individually) and dissolved in concentrated nitric acid (∼10 mL) with heating on a water bath at 80 °C for 120 min. The solution was cooled and 50 mL deionized water was added to it and filtered by using cellulose membrane of 0.45 μm pore size (Millipore). The filtrate (approximately 60 mL) was made to 100.0 mL with deionized water in a calibrated flask. An aliquot (50 mL) of the sample solution was taken individually, and the analyte ions were determined by the coprecipitation procedure.
Water samples were collected in acid leached polyethylene bottles. The only pretreatment was acidification to pH 2 with nitric acid, which was performed immediately after collection, in order to prevent adsorption of the metal ions on the flask walls. The samples were filtered before analyses through a cellulose membrane of 0.45 μm pore size (Millipore).
3 Results and discussion
At first the precipitate of Co(OH)2, insoluble in water, was formed in pH 11.0 and then the analyte ions were accumulated on the coprecipitant (Co(OH)2) over various mechanisms surface adsorption, ion-exchange, surface precipitation, and occlusion (Soylak and Onal, 2006). The influence of the various analytical parameters such as pH, amount of carrier element, standing time, centrifugation rate and time, sample volume and matrix effects on the recovery of the analyte ions was examined. The optimizations were carried out on 50 mL of an aqueous solution containing 5.0 ng mL−1 of Cu(II), Ni(II), Mn(II) and 1.0 ng mL−1 of Cd(II). Each experiment was repeated four times and averaged values are given as the results.
3.1 Effects of pH
The pH of the sample solutions was adjusted in a range of 7–12 by using diluted NaOH and the coprecipitation procedure was applied to this solutions. As can be seen in Fig. 1, the absorbance of the analyte ions increased with increase in pH and the maximum absorbance for copper, nickel and manganese obtained at the pH range 10.5–12, whereas the maximum absorbance for cadmium was obtained at the pH range 10.5–11.5. After pH 11.5, the absorbance of Cd(II) decreased with increasing of pH. Therefore, pH 11 was selected as optimum pH in all subsequent works for separation and preconcentration of the analyte ions.
3.2 Effect of amount of carrier element
The influence of amount of carrier element is an essential consideration for efficient extraction in coprecipitation procedure. For investigating the influence of amount of Co2+ as a carrier element on the coprecipitation procedure performance, several experiments were performed by adding varying amounts of Co2+ from 0.0 to 3.0 mg. The rest of the experimental conditions were kept constant. The results showed that, the absorbance of the analyte ions increased and reach to quantitative value for the analyte ions at the range of 1.0–3.0 mg. Therefore, 1.25 mg Co2+ was selected in all subsequent works.
3.3 Effect of standing time, centrifugation rate and time
The standing time, centrifugation rate and time were also examined. For investigating the influence of the standing time, 1.25 mL of Co2+ 1000.0 mg L−1 was added into 50 mL of an aqueous solution containing 5.0 ng mL−1 of Cu(II), Ni(II), Mn(II) and 1.0 ng mL−1 of Cd(II). Then, the standing time was investigated in the range of 0–20 min. The results showed that after 8 min, quantitative recoveries were obtained. Therefore, 10 min was selected as optimum standing time for all subsequent experiments. The effect of the centrifugation speed on the extraction of the analyte ions was investigated in the range of 1000–5000 rpm for 5 min. The results showed that, the maximum extraction was obtained for the analyte ions at 4000 rpm. Therefore, all further studies were performed at 4000 rpm.
The effect of centrifugation time on the extraction of the analyte ions was tested in the range of 2–15 min at 4000 rpm. The results showed that maximum extraction was obtained for the analyte ions in the range of 4–15 min. Therefore, 5 min was selected as optimum centrifugation time for all subsequent experiments.
3.4 Effect of sample volume
The effect of sample volume is a very important parameter in coprecipitation procedure (Sun, 1993; Uluozlu et al., 2009). To this purpose, the influence of the sample volume on the coprecipitation efficiency of the analyte ions was examined. In order to explore the possibility of enriching analytes from natural water with a high preconcentration factor, a series of sample solutions, containing 250.0 ng of Cu(II), Ni(II), Mn(II) and Cd(IfI) were studied in the volume range 20–600 mL at the optimum conditions. The results showed that the quantitative extractions were obtained for the analyte ions in the range of 20–500 mL. Therefore, 25 mL was selected as sample volume for all subsequent experiments. With respect to the final elution volume of 2.0 mL of HNO3 and a breakthrough volume of 500 mL, a preconcentration factor of 250 was achievable.
3.5 Effect of foreign ion
Matrix effect is an important problem in the determination of heavy metals in the real samples. The effect of some important diver’s ions on the absorbance of the analyte ions was also examined. For this study, 50 mL of an aqueous solution containing 5.0 ng mL−1 of Cu(II), Ni(II), Mn(II) and 1.0 ng mL−1 of Cd(II) was taken and different amounts of foreign ions were added to it and coprecipitation procedure was followed. Tolerable limit was defined as the highest amount of foreign ions that produced an error not exceeding ±5% in the determination of Cu(II), Ni(II), Mn(II) and Cd(II) ions. The results are given in Table 2. The results showed that large numbers of anions and cations used have no considerable effect on the determination of Cu(II), Ni(II), Mn(II) and Cd(II) ions.
| Foreign ions | Interference/analyte ions(II) ratioa | |||
|---|---|---|---|---|
| Cu(II) | Ni(II) | Mn(II) | Cd(II) | |
| H2PO4−, HPO42− | 5000 ± 208 | 5000 ± 235 | 6000 ± 190 | 6000 ± 179 |
| NO3−, CH3COO−, Na+, K+ | 7500 ± 30 | 5200 ± 83 | 6700 ± 28 | 6400 ± 34 |
| SO42− | >10,000 | >10,000 | >10,000 | >10,000 |
| Cl− | >10,000 | >10,000 | >10,000 | >10,000 |
| Ca2+ | 2500 ± 103 | 2500 ± 96 | 3000 ± 98 | 2500 ± 109 |
| Mg2+ | 3000 ± 121 | 3000 ± 128 | 2500 ± 114 | 2500 ± 110 |
| Al3+ | 500 ± 17 | 250 ± 9 | 250 ± 7 | 200 ± 6 |
| Ag+ | 500 ± 21 | 400 ± 12 | 400 ± 13 | 500 ± 18 |
| Ba2+ | 300 ± 10 | 300 ± 11 | 250 ± 6 | 300 ± 9 |
| Cr3+ | 500 ± 16 | 600 ± 19 | 500 ± 17 | 500 ± 15 |
| Zn2+ | 200 ± 8 | 150 ± 7 | 200 ± 7 | 200 ± 8 |
| Fe3+ | 200 ± 11 | 250 ± 12 | 200 ± 10 | 200 ± 6 |
| Pb2+ | 400 ± 21 | 500 ± 28 | 500 ± 18 | 400 ± 19 |
3.6 Calibration, precision and detection limits
Calibration curves were obtained by coprecipitation 50.0 mL of a sample solution containing of known amounts of four analyte ions under the optimized conditions. Enrichment factor was calculated as the ratio of the slope of calibration curve after and before of microextraction. The enrichment factors for Cu(II), Ni(II), Mn(II) and Cd(II) ions were 24.7, 22.7, 23.9 and 24.4, respectively. The reproducibility and the repeatability were evaluated with 50 mL of an aqueous solution containing 5.0 ng mL−1 of Cu(II), Ni(II), Mn(II) and 1.0 ng mL−1 of Cd(II). The repeatability (intra-day) and reproducibility (inter-day) of the method were evaluated by carrying out seven replicate extraction and determination of the analyte ions during a day (intra-day) and seven replicates at seven subsequent days (inter-day). The results were reported in Table 3. The detection limits based on 3Sb/m for Cu(II), Ni(II), Mn(II) and Cd(II) in the original solution were 0.2, 0.2, 0.3 and 0.07 ng mL−1, respectively. Analytical parameters of the method are given in Table 3.
| Statistical parameters | Cu | Ni | Mn | Cd |
|---|---|---|---|---|
| Linear ranges (ng mL−1) | 6.7–200.0 | 6.7–200.0 | 10.0–250.0 | 2.3–80.0 |
| Regression equations | A = 2.2173X + 0.0014 | A = 2.8776X + 0.0015 | A = 2.3969X + 0.0028 | A = 8.5183X + 0.0039 |
| Correlation coefficient (R) | 0.9992 | 0.9994 | 0.9998 | 0.9984 |
| RSDa % (Intra-day, n = 7) | 1.9 | 1.7 | 1.8 | 2.1 |
| RSD % (Inter-day, n = 7) | 2.1 | 1.9 | 2.2 | 2.6 |
| Detection limit (ng mL−1) | 0.2 | 0.2 | 0.3 | 0.07 |
Conditions: Volume of the original solution, 50 mL, volume of the final solution, 2.0 mL, and other conditions were the same as Fig. 1.
3.7 Accuracy of the method
The accuracy and applicability of the proposed coprecipitation procedure has been applied to the determination of Cu(II), Ni(II), Mn(II) and Cd(II) ions in National Institute for Environment Studies (NIES) No. 1 Pepperbush and NIES No. 7 Tea Leaves. Results are given in Table 4. It was found that there is no significant difference between results obtained by the coprecipitation procedure and the certified results. These results indicate the applicability of the coprecipitation procedure for copper, nickel, manganese and cadmium determination is free of interference.
| Sample | Composition | Founda (μg g−1) |
|---|---|---|
| NIES, No. 1 Pepperbush b | K, 1.51 ± 0.06, Mn, 0.203 ± 0.17, Ca, 1.38 ± 0.07, Mg, 0.408 ± 0.020%, Cd, 6.7 ± 0.5, Ni, 8.7 ± 0.6, Cu, 12 ± 1, Cs, 1.2, Tl, 0.13, Fe, 205 ± 17, Co, 23.0 ± 3, Pb, 5.5 ± 0.8, P, 1100, Cr, 1.3, Zn, 340 ± 20, Ba, 165 ± 10, Sr, 36 ± 4, As, 2.3 ± 0.3, Rb, 75 ± 4, Na, 106 ± 13, Hg, 0.05 μg g−1 | Cu: 12.2 ± 0.6 |
| Ni: 8.6 ± 0.5 | ||
| Cd: 6.8 ± 0.5 | ||
| NIES, No. 7 Tea Leaves | Pb, 0.80, Cd, 0.030, Sb, 0.014, Zn, 33, Cr, 0.15, Al, 775, Mg, 1530, Ba, 5.7, K, 18,600, Sc, 0.011, Na, 15.5, Sr, 3.7, Ca, 3200, Cs, 0.22 l, Co, 0.12, Mn, 7.00, Ni, 6.5, Cu, 7.0 μg g−1 | Cu: 6.9 ± 0.3 |
| Ni: 6.7 ± 0.5 | ||
| Mn: 7.0 ± 0.3 | ||
| Cd: 0.032 ± 0.003 | ||
3.8 Applications
The proposed coprecipitation procedure has been also applied to different natural waters for the enrichment and separation of the analyte ions. The results are given in Table 5. The utility of the coprecipitation procedure was also evaluated by examining the recoveries of the analyte ions from water samples spiked with the standard analytes. According to this Table, the added Cu(II), Ni(II), Mn(II) and Cd(II) ions can be quantitatively recovered from the water samples by the coprecipitation procedure. These results demonstrate the applicability of the procedure for copper, nickel, manganese and cadmium ions determination in water samples. The recovery of copper, nickel, manganese and cadmium added to the samples demonstrates the efficiency of the proposed procedure.
| Sample | Founda (ng mL−1) | Add values (ng mL−1) | Found (ng mL−1) | Recovery values after additiona (%) |
|---|---|---|---|---|
| Well water (Payame Noor University of Kerman) | Cu: 3.1 ± 0.1 | Cu: 10.0 | Cu: 13.3 ± 0.6 | 102.0 ± 0.9 |
| Ni: 7.4 ± 0.3 | Ni: 10.0 | Ni: 17.6 ± 0.8 | 102.0 ± 1.2 | |
| Mn: 8.9 ± 0.4 | Mn: 10.0 | Mn: 19.3 ± 1.0 | 104.0 ± 0.4 | |
| Cd: 2.31 ± 0.04 | Cd: 10.00 | Cd: 12.50 ± 0.04 | 101.9 ± 1.0 | |
| River Water (Rayen, Kerman) | Cu: 5.8 ± 0.3 | Cu: 10.0 | Cu: 15.5 ± 0.6 | 97.0 ± 0.4 |
| Ni: 6.5 ± 0.3 | Ni: 10.0 | Ni: 16.8 ± 0.7 | 103.0 ± 0.7 | |
| Mn: 6.4 ± 0.4 | Mn: 10.0 | Mn: 16.2 ± 0.6 | 98.0 ± 0.2 | |
| Cd: 1.08 ± 0.04 | Cd: 10.00 | Cd: 11.19 ± 0.04 | 101.1 ± 0.7 | |
| River Water (Shahdad, Kerman) | Cu: 7.9 ± 0.4 | Cu: 10.0 | Cu: 18.2 ± 0.7 | 103.0 ± 1.4 |
| Ni: 7.6 ± 0.3 | Ni: 10.0 | Ni: 17.5 ± 0.6 | 99.0 ± 0.9 | |
| Mn: 7.1 ± 0.4 | Mn: 10.0 | Mn: 16.9 ± 0.6 | 98.0 ± 1.1 | |
| Cd: 1.27 ± 0.06 | Cd: 10.00 | Cd: 11.17 ± 0.61 | 99.0 ± 0.3 | |
3.9 Comparison of the proposed method with the other methods
A comparison of the proposed coprecipitation procedure with the other reported preconcentration methods (Saracoglu et al., 2003; Uluozlu et al., 2010; Doner and Ege, 2005; Soylak and Onal, 2006; Ghaedi et al., 2008) for the copper, nickel, manganese and cadmium extraction from water samples are given in Table 6. The obtained detection limits, RSD% and linear range by the coprecipitation procedure are comparable or better than most of those reported in the literature.
| System | Analysis method | Sample volume (mL) | RSD (%) | Linear range (ng mL−1) | LOD (ng mL−1) | Refs. |
|---|---|---|---|---|---|---|
| Coprecipitation | FAAS | 10 | 5% | – | Cu: 1.1 | Saracoglu et al. (2003) |
| Ni: 3.1 | ||||||
| Mn: 1.0 | ||||||
| Cd: 0.4 | ||||||
| Coprecipitation | FAAS | 50 | 3.8% | 250–5000 | Cu: 1.3 | Uluozlu et al. (2010) |
| Coprecipitation | FAAS | 50 | 2–3% | – | Cu: 3.0 | Doner and Ege (2005) |
| Cd: 6.0 | ||||||
| Coprecipitation | FAAS | 10 | 1–10% | – | Mn: 1.7 | Soylak and Onal (2006) |
| Cloud point extraction | FAAS | 15 | Cu: 1.2 | Cu: 10–250 | Cu: 1.6 | Ghaedi et al. (2008) |
| Ni: 1.3 | Ni: 10–200 | Ni: 1.9 | ||||
| Coprecipitation | FAAS | 50 | Cu: 1.9 | Cu: 0.5–200.0 | Cu: 0.2 | Present work |
| Ni: 1.7 | Ni: 0.5–200.0 | Ni: 0.2 | ||||
| Mn: 1.8 | Mn: 0.5–250.0 | Mn: 0.3 | ||||
| Cd: 1.1 | Cd: 0.3–80.0 | Cd: 0.07 | ||||
4 Conclusions
The coprecipitation with cobalt hydroxide system without chelating agent offers a useful multielement preconcentration technique in environmental samples. The main benefits of the coprecipitation procedure were as follows: simplicity, low cost, enhancement of sensitivity, rapid analysis time and high enrichment factor. Also, the coprecipitation procedure does not need any chelating agent.
Acknowledgments
The authors thank Payame Noor University for the financial support of this work.
References
- Preconcentration procedure trace amounts of palladium using modified multiwalled carbon nanotubes sorbent prior to flame atomic absorption spectrometry: 1st Nano Update. Arab. J. Chem.. 2012;5:461-466.
- [Google Scholar]
- Application of modified multiwalled carbon nanotubes as solid sorbent for separation and preconcentration of trace amounts of manganese ions. Arab. J. Chem.. 2012;5:187-191.
- [Google Scholar]
- Preconcentration, separation and spectrophotometric determination of aluminium(III) in water samples and dialysis concentrates at trace levels with 8-Hydroxyquinoline–cobalt(II) coprecipitation system. J. Hazard. Mater.. 2010;182:331-336.
- [Google Scholar]
- Speciation and determination of thallium by on-line micro column separation/preconcentration by flow injection–flame atomic absorption spectrometry using immobilized oxine as sorbent. J. Hazard. Mater.. 2007;148:446-452.
- [Google Scholar]
- Determination of some trace metals in water and sediment samples by flame atomic absorption spectrometry after coprecipitation with cerium (IV) hydroxide. Anal. Chim. Acta. 2002;452:231-235.
- [Google Scholar]
- Determination of copper, cadmium and lead in seawater and mineral water by flame atomic absorption spectrometry after coprecipitation with aluminum hydroxide. Anal. Chim. Acta. 2005;547:14-17.
- [Google Scholar]
- On-line separation and preconcentration of lead(II) by solid-phase extraction using activated carbon loaded with xylenol orange and its determination by flame atomic absorption spectrometry. J. Hazard. Mater.. 2008;150:554-559.
- [Google Scholar]
- Cloud point extraction for the determination of copper, nickel and cobalt ions in environmental samples by flame atomic absorption spectrometry. J. Hazard. Mater.. 2008;150:533-540.
- [Google Scholar]
- Heavy metals determination in water and food samples after preconcentration by a new nanoporous adsorbent. Food Chem.. 2013;141:1916-1922.
- [Google Scholar]
- Synthesis and characterisation of morin-functionalised silica gel for the enrichment of some precious metal ions. Talanta. 2006;68:1550-1559.
- [Google Scholar]
- Risks of using membrane filtration for trace metal analysis and assessing the dissolved metal fraction of aqueous media – a study on zinc, copper and nickel. Environ. Pollut.. 2011;159:1144-1150.
- [Google Scholar]
- Copper recovery from ore by liquid–liquid extraction using aqueous two-phase system. J. Hazard. Mater.. 2012;209:237-238.
- [Google Scholar]
- Comparison of pre-reducing agents for antimony determination by hydride generation atomic fluorescence spectrometry. Anal. Chim. Acta. 2004;511:295-302.
- [Google Scholar]
- Simultaneous separation/preconcentration of ultra trace heavy metals in industrial wastewaters by dispersive liquid–liquid microextraction based on solidification of floating organic drop prior to determination by graphite furnace atomic absorption spectrometry. J. Hazard. Mater.. 2011;186:1739-1743.
- [Google Scholar]
- Flame atomic absorption spectrometric determination of trace amounts of lead, cadmium and nickel in different matrixes after solid phase extraction on modified multiwalled carbon nanotubes. Cent. Eur. J. Chem.. 2010;8:662-668.
- [Google Scholar]
- Ultrasound-assisted emulsification microextraction of trace amounts of Co and Mn ions prior to flame atomic absorption spectrometry. J. Braz. Chem. Soc.. 2011;22:104-110.
- [Google Scholar]
- Separation of trace amounts palladium by SiO2/TiO2/Ce nanoparticles prior to flame atomic absorption spectrometry determination in anodic slime and wastewater samples. Cent. Eur. J. Chem.. 2013;11:1749-1756.
- [Google Scholar]
- Simultaneous extraction of trace amounts of cobalt, nickel and copper ions using magnetic iron oxide nanoparticles without chelating agent. J. Anal. Chem.. 2013;68:953-958.
- [Google Scholar]
- Mohammadi, S.Z., Shamspur, T., Afzali, D., Taher, M.A., Baghelani, Y.M., 2016. Applicability of cloud point extraction for the separation trace amount of lead ion in environmental and biological samples prior to determination by flame atomic absorption spectrometry. Arab. J. Chem. 9, S610–S615.
- Removal of nickel(II) and palladium(II) from surface waters. Bull. Chem. Soc. Ethiopia. 2013;27:15-23.
- [Google Scholar]
- Separation/preconcentration of trace heavy metals in urine, sediment and dialysis concentrates by coprecipitation with samarium hydroxide for atomic absorption spectrometry. Talanta. 2003;59:287-293.
- [Google Scholar]
- A preconcentration procedure using coprecipitation for determination of lead and iron in several samples using flame atomic absorption spectrometry. Anal. Chim. Acta. 2006;575:133-137.
- [Google Scholar]
- Determination of trace metals by atomic absorption spectrometry after coprecipitation with europium hydroxide. J. Hazard. Mater.. 2006;137:1130-1134.
- [Google Scholar]
- Coprecipitation of gold(III), palladium(II) and lead(II) for their flame atomic absorption spectrometric determinations. J. Hazard. Mater.. 2008;152:656-661.
- [Google Scholar]
- Determination of antimony(III, V) in natural waters by coprecipitation and neutron activation analysis. Anal. Chim. Acta. 1993;276:33-37.
- [Google Scholar]
- Application of multiwall carbon nanotubes impregnated with 5-dodecylsalicylaldoxime for on-line copper preconcentration and determination in water samples by flame atomic absorption spectrometry. Talanta. 2012;96:89-95.
- [Google Scholar]
- Multi-element coprecipitation for separation and enrichment of heavy metal ions for their flame atomic absorption spectrometric determinations. J. Hazard. Mater.. 2009;162:724-729.
- [Google Scholar]
- Speciation and separation of Cr(VI) and Cr(III) using coprecipitation with Ni2+/2-Nitroso-1-naphthol-4-sulfonic acid and determination by FAAS in water and food samples. Food Chem. Toxicol.. 2009;47:2601-2605.
- [Google Scholar]
- Coprecipitation of trace elements with Ni2+/2-Nitroso-1-naphthol-4-sulfonic acid and their determination by flame atomic absorption spectrometry. J. Hazard. Mater.. 2010;176:1032-1037.
- [Google Scholar]
- Bestimmung von Spuren Titan und Zirkonium in Molybdän und Wolfram bzw. deren Sauerstoffverbindungen durch Röntgenfluorescenz-Spektralanalyse (RFA) Fresenius Z. Anal. Chem.. 1977;284:101-105.
- [Google Scholar]
- Sorption of iron(II) and ruthenium(III)-triazine complexes on silica gel and its analytical applicability. Arab. J. Chem.. 2013;6:111-114.
- [Google Scholar]
- Differential determination of trace amounts of arsenic(III) and arsenic(V) in seawater by solid sampling atomic absorption spectrometry after preconcentration by coprecipitation with a nickel– pyrrolidine dithiocarbamate complex. Anal. Chim. Acta. 2004;508:99-105.
- [Google Scholar]
