5.2
Impact Factor
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Corrigendum
Current Issue
Editorial
Erratum
Full Length Article
Full lenth article
Letter to Editor
Original Article
Research article
Retraction
Retraction notice
Review
Review Article
SPECIAL ISSUE: ENVIRONMENTAL CHEMISTRY
5.3
Impact Factor
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Corrigendum
Current Issue
Editorial
Erratum
Full Length Article
Full lenth article
Letter to Editor
Original Article
Research article
Retraction
Retraction notice
Review
Review Article
SPECIAL ISSUE: ENVIRONMENTAL CHEMISTRY
View/Download PDF
Original Article
ARTICLE IN PRESS
doi:
10.25259/AJC_517_2026

Translate:

Simultaneous electrochemical detection of cholecalciferol and linezolid using cobalt oxide / Calcium lead ferrite nanohybrid

Author affiliations
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Hyderabad, Pakistan
Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh, Saudi Arabia
Dr. M.A Kazi Institute of Chemistry, University of Sindh, Jamshoro, Hyderabad, Pakistan
Article History
Corresponding author(s)

* Corresponding author: E-mail address: jamughal@imamu.edu.sa (J.A. Baig)

Article tools · PDF & citations

Abstract

This study presents the synthesis of a cobalt oxide-functionalized calcium lead ferrite nanohybrid (CoO/CaPbFe₂O₄-NH) and its application as an efficient electrochemical sensor for the simultaneous detection of cholecalciferol (CFO) and linezolid (LZD). The fabricated CoO/CaPbFe₂O₄-NH-modified glassy carbon electrode exhibited excellent electrocatalytic activity, enabling sensitive and selective detection of both analytes in Britton–Robinson buffer (pH 9.0). The sensor demonstrated a wide linear response with low detection limits of 1.7 nM for CFO and 5.2 nM for LZD. The enhanced sensing performance is attributed to the synergistic effect, high surface area, and improved electron transfer properties of the nanohybrid material. Furthermore, the developed sensor demonstrated good applicability to the analysis of pharmaceutical and healthcare samples, indicating its potential for practical use.

Keywords

  • Analytical techniques
  • CoO/CaPbFe₂O₄-NH/GCE
  • Health care products
  • Linezolid
  • cholecalciferol
  • Pharmaceuticals
Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

1. Introduction

In recent times, residues of pharmaceutical and healthcare products in water have become a leading environmental problem. Several studies have shown that even small amounts of pharmaceuticals can harm living organisms, affecting human health and the environment. The remains of pharmaceuticals (analgesics, antibiotics, antiarrhythmics, antacids, anticoagulants, anxiolytics, antidepressants, antifungals, anti-inflammatories, and stimulants, etc.) and health care products (calciferol, probiotics, calcitriol, magnesium glycinate, calcifediol, creatine, omega-3, organic deodorant, etc.) are preserved in the environment even at trace levels [1,2]. The extensive use of pharmaceuticals and the inappropriate discarding of their remains lead to numerous health problems. The potential harm, bioaccumulation, and interference with biological systems make remnants in water unsafe for aquatic life and human health. In this regard, it is necessary to detect these emerging pollutants to protect life and ecosystems [2,3]. In addition, the trace amounts of pharmaceuticals remaining in the environment, their structural variety, and interference affect the analysis of pharmaceuticals and other healthcare residues in water.

Unfortunately, the typical water purification systems available today have not been designed to remove the micropollutants that continually enter water systems. Analytical methods such as spectrometry and chromatography are useful, but they cannot be used on-site because they require expensive chemicals, complex equipment, and lengthy sample preparation times [4,5]. Nevertheless, for real-time detection of such pollutants, electrochemical sensing offers a more portable, sensitive, and cost-effective approach. The properties of the electrode material play a vital role in the performance of an electrochemical sensor. The need to develop new materials with enhanced electrochemical properties cannot be overlooked, as conventional materials may have limitations, including low sensitivity and selectivity [6-8].

Nanotechnology has transformed electrochemical sensing by enabling the synthesis of nanosized materials with distinct physicochemical features, such as large surface area, variable shapes, and improved electrical conductivity. Because of their many uses, such as catalytic activity, magnetic recoverability, and superior sensing performance, magnetic nanohybrids have attracted considerable interest [3,9-11]. In addition to avoiding the use of hazardous chemicals, the green synthesis process is used to obtain biocompatible nanohybrids. Plant extracts help create nanoparticles with regulated shapes and improve performance by acting as natural reducing, stabilizing, and capping agents [12].

Among various nanomaterials, transition-metal oxides and ferrite-based nanostructures have gained significant attention for their excellent electrocatalytic activity, chemical stability, and tunable electronic properties. In this context, cobalt oxide (CoO) is widely recognized for its multiple oxidation states (Co2⁺/Co3⁺), which facilitate rapid electron transfer and enhance redox reactions. On the other hand, calcium lead ferrite (CaPbFe₂O₄) provides a stable mixed-metal oxide framework with high surface area and abundant active sites, promoting efficient adsorption of analyte molecules [13]. The combination of CoO with CaPbFe₂O₄ results in a synergistic nanohybrid structure, where CoO enhances charge transfer kinetics while CaPbFe₂O₄ improves structural stability and analyte interaction [14,15]. This synergistic effect significantly improves the sensitivity, selectivity, and overall electrochemical performance of the sensor, making it a suitable choice for the simultaneous detection of pharmaceutical compounds such as cholecalciferol (CFO) and linezolid (LZD).

There are two primary forms of vitamin D, both of which are fat-soluble. These are known as vitamin D2, also called ergocalciferol (EFO), and vitamin D3, also called CFO [16]. They are very similar structurally but differ in details, such as an extra methyl group and a double bond. Both vitamins can be synthesized naturally in the body from precursors, including ergosterol for vitamin D2 and 7-dehydrocholesterol for vitamin D3, after exposure to sunlight. According to various research findings, vitamin D deficiency during avitaminosis impairs the absorption of calcium and phosphorus. It is associated with various health issues, including cardiovascular disease, high blood pressure, cancers, and other complications [16,17]. Today, due to a modern lifestyle where people spend much of their time inside their houses, leading to minimal exposure to sunlight, particularly in countries receiving less annual sunshine, a significant percentage of the world’s population lacks vitamin D. Consequently, apart from ingesting food items rich in vitamin D, including fish oil, mushrooms, eggs, and dairy products, vitamin D fortification in food items and supplement intake is a common practice worldwide [18]. There are two forms of vitamin D, namely EFO and CFO; various studies indicate that CFO is more effective than EFO at increasing vitamin D levels in the body [19]. Today, CFO is the most popular choice for vitamin D supplementation [20].

On the contrary, in terms of hospitalized patients across the world, there are strong factors that contribute to sickness and mortality rates as a result of MRSA infections [21]. MRSA infections are prevalent in the Mediterranean region, and Egypt leads in MRSA clinical isolates [21,22]. The first drug used to treat MRSA infections is Vancomycin, but it has several limitations, including Vancomycin-associated resistance and nephrotoxicity [21,23]. Consequently, another antibiotic, LZD, was developed and is Food and Drug Administration (FDA)-approved for treating patients with pneumonia and skin and soft tissue infections caused by MRSA, as well as vancomycin-resistant Enterococcus faecium infections [21]. All hospital-acquired pneumonia and pneumonia patients, including those who require ventilators, account for approximately 20 to 40 percent of all the identified patients [21,24]. Recently, the Infectious Diseases Society of America and the American Thoracic Society have developed guidelines that recommend the use of LZD as the initial therapy in pneumonia [21].

Therefore, quantifying both beneficial biomolecules, such as CFO, and hazardous contaminants, such as LZD, in food and water is necessary to ensure food safety, nutritional quality, and public health protection. In the current study, cobalt oxide-calcium lead ferrite nanohybrid (CoO/CaPbFeO₄-NH) was synthesized by the green method and fabricated onto a bare GCE for the development of CoO/CaPbFeO₄-NH/GCE: K. The incorporation of CoO in CaPbFe2O4 enhances the stability, redox properties, and reactivity of the material, making it suitable for combined sensing. Characterization of the CoO/CaPbFe2O4-NH compound was performed using various methods to determine its structural, size, and morphological characteristics. Despite numerous studies on various analyte detection, simultaneous electrochemical sensing of CFO and LZD using green-synthesized nanomaterials remains underexplored. The CoO/CaPbFeO₄-NH/GCE-based differential pulse voltammetry (CoO/CaPbFeO₄-NH/GCE/DPV) method was applied to detect CFO and LZD simultaneously in wastewater samples.

2. Materials and Methods

2.1. Chemicals and reagents

Sigma-Aldrich (Louis, USA) provided a variety of materials, including lizolid (≥ 99%), cholecalciferol (CFO; ≥ 99%), hydrochloric acid, phosphoric acid, boric acid, sodium acetate, potassium ferrocyanide, potassium chloride, and potassium ferricyanide, which are used in the current research project. Nafion (NR50), iron nitrate nonahydrate (Fe (NO3)3.9H2O), calcium nitrate; Ca (NO3)2.2H2O, lead nitrate; Pb (NO₃)₂, cobalt acetate; Co(CH3CO2)2·4 H2O, sodium hydroxide (NaOH), ammonia (NH3), and alumina powder (0.3 µm and 0.5µm) were obtained from Fluka (Bush, Switzerland). Additionally, the deionized water (DIW) was supplied by a water purifier (Bedford, USA).

2.2. Synthesis of CaPbFe2O4 nanoparticles (NPs)

The fresh Babur (Vachellia nilotica) plant leaves were washed many times with tap water and then with deionized water. The leaves were dried at 70°C in the oven for 30 min to remove moisture, then cut into pieces with stainless steel scissors and washed with ethanol. A 250 mL conical flask containing 30 g of leaves and 250 mL of deionized water was heated to 80.0°C for 3 h. The extract was further filtered with Whatman filter paper. 0.5:0.5:2 of calcium:lead: iron nitrate salts were dissolved in 50:50:100 mL of distilled water separately. 50 mL of extract was added to the calcium and lead nitrate, and 100 mL to the iron nitrate solution. The solution was stirred and mixed, followed by maintaining the pH at 7 to 9 using ammonia solution while heating at 80°C. The precipitates of CaPbFe2O₄-NPs were produced. It was dried in an oven at 70°C for 24 h after the sediment was removed and the sample was rinsed with water.

2.3. Fabrication of CoO/CaPbFe2O₄ nanohybrid

The CaPbFe2O₄-NPs powder sample (0.1 g) was mixed with 50 mL of cobalt acetate solution at a concentration of 2 µM. After filtering, the residues were recovered, and the resultant solutions were kept at pH 12 using NaOH (0.1 M). To synthesize CoO/CaPbFe2O₄-NH, the resultant precipitates were heated to 400°C and calcined for 2 h in a muffle furnace [25].

2.4. Modification of CoO/CaPbFe2O₄-NH/GCE

The surface of the GCE was first gently abraded with alumina paste and then sonicated in an ethanol/deionized water mixture. The GCE was then thoroughly washed with water several times and air-dried. The CoO/CaPbFe2O₄-NH/GCE was fabricated using the drop-casting process. CoO/CaPbFe2O₄-NH was added to deionized water, followed by 100 µL of 0.5% Nafion solution as a conductive binder for drop casting. The mixture was sonicated for 30 min to disperse it. The polished GCE surface was then coated with 10 µL of the prepared suspension and dried at room temperature. The modified sensor was used to detect the CFO and LZD using the CoO/CaPbFe2O₄-NH/GCE/DPV method.

2.5. Instrumentation

The pH of the solution was regulated with a pH meter (Eutech, Malaysia). The crystallite size and behavior were ascertained using the X-ray diffraction (XRD) technique (D-8, Bruker), and the surface morphology and elemental composition of the synthesized material were examined using SEM and EDX, respectively (JSM-6380 JEOL Electronics, Japan. The AFM (D-8, Bruker) technique was used to analyze the surface topography of synthesized materials.

2.6. Electrochemical analysis procedure

The CHI electrochemical analyzer from Tennison Hill Drive, Austin, USA, was used for voltammetric analysis. The voltammogram was examined using a three-electrode cell with three electrodes. The reference electrode used was Ag/AgCl/KCl (2.0 mol L-1), while the CoO/CaPbFe2O4-NH/GCE and platinum wire were taken as the working and auxiliary electrodes, respectively. Under optimal conditions, such as the presence of a quiet time of 2 s, a sampling width of 0.02 s, a pulse period of 0.2 s, an amplitude of 50 mV, and a pH 9.0 Britton-Robinson buffer (BRB), the DPV technique was applied.

2.7. Sample preparation

Wastewater samples were taken from three different sites in Jamshoro. The collected samples underwent a well-defined pretreatment procedure prior to electrochemical analysis. Initially, the samples were filtered using a 0.45 μM membrane filter to remove suspended particulate matter. The filtered samples were then appropriately diluted with BR buffer solution to bring the analyte concentration within the method’s linear working range. Subsequently, the solution pH was adjusted to 9.0 using BR buffer to ensure optimal electrochemical response. For real samples, a standard addition method was employed to minimize matrix effects. Where necessary, the samples were subjected to a brief adsorption step by mixing with the modified electrode material to enhance analyte preconcentration, followed by equilibration under gentle stirring. Before measurement, the CoO/CaPbFe₂O₄-NH-modified glassy carbon electrode (CoO/CaPbFe₂O₄-NH/GCE) was electrochemically conditioned by performing cyclic voltammetry scans in blank BR buffer to stabilize the electrode surface. After completing these pre-treatment steps, the samples were analyzed by DPV to determine the concentrations of CFO and LZD.

3. Results and Discussion

3.1. Characterization of CoO/CaPbFe2O₄-NH

The results obtained from the XRD analysis are analyzed to identify the crystal structure and crystalline size of the CaPbFe₂O₄-NPs and CoO/CaPbFe₂O₄-NH (Figure 1a). The XRD pattern of the synthesized CaPbFe₂O₄ nanoparticles exhibits well-defined diffraction peaks at 2θ values of approximately 21°, 28°, 33°, 36°, 40°, 49°, 55°, 65°, and 74°, which were indexed to the reflections (220), (310), (320), (040), (131), (401), (431), (170), and (042), respectively. These diffraction peaks are consistent with the reported orthorhombic ferrite structure of CaPbFe₂O₄ (space group Pnma), confirming the successful formation of the target phase with high crystallinity. Despite the absence of a definitive powder XRD pattern for CaPbFe₂O₄ in the JCPDS/ICDD database, structural data and the crystallographic positions of atoms in Pb-calcium-ferrites are similar to the PbFe₂O₄ structure type reported in previous studies [14,15]. Following the fabrication process through the addition of cobalt oxide, the X-ray diffraction profile of the CoO/CaPbFe₂O₄-NH sample reveals no new diffraction peaks, implying that there is no new crystalline phase, such as cobalt oxide, formed beyond the limits of detection. The main diffraction peaks characteristic of CaPbFe₂O₄-NPs are retained in their position. However, they are sharper and more intense, suggesting increased crystallinity. For reference, the standard diffraction pattern for cobalt ferrite (CoFe₂O₄), a common cubic spinel cobalt oxide phase, is catalogued under JCPDS Card No. 22-1086, exhibiting characteristic reflections such as (220), (311), (400), (422), (511), and (440) in the range of ∼30–65° 2θ [26]. The absence of any new peaks in the cobalt oxide-coated sample indicates either an amorphous structure or high dispersion of CoO on the CaPbFe₂O₄ surface, or that there is an overlap between the peaks of the cobalt oxide phases and the peaks of the host phase. Furthermore, the increased peak intensity in the cobalt oxide-coated sample indicates improved crystallographic ordering rather than the crystallization of separate cobalt oxides. The % crystallinity of synthesized CaPbFe₂O₄ nanoparticles was 80 %, and that of the CoO/CaPbFe₂O₄-NH was 81 % [12]. The average size of the synthesized CaPbFe₂O₄-NPs and CoO/CaPbFe₂O₄-NH has been calculated using the Debye-Scherrer formula, and the calculated average sizes are 15.2 nm and 20.8 nm, respectively.

(a) XRD, (b) FTIR spectra of synthesized CaPbFe₂O₄-NPs and the CoO/CaPbFe₂O₄-NH, (c) SEM image of CaPbFe₂O₄-NPs and (d) SEM image of CoO/CaPbFe₂O₄-NH.
Figure 1. (a) XRD, (b) FTIR spectra of synthesized CaPbFe₂O₄-NPs and the CoO/CaPbFe₂O₄-NH, (c) SEM image of CaPbFe₂O₄-NPs and (d) SEM image of CoO/CaPbFe₂O₄-NH.

FTIR analysis of CaPbFe₂O₄ and CoO/CaPbFe₂O₄ nanohybrid was done to analyze the functional groups and verify the introduction of CoO into the CaPbFe₂O₄ nanohybrid (Figure 1b). The FTIR spectra of CaPbFe₂O₄ and CoO/CaPbFe₂O₄-NH in the range of 400 to 2000 cm⁻1 depict the presence of vibrational bands for the M-O lattice and surface hydroxyl groups. The bending vibration of the surface hydroxyl groups at about 1410 cm⁻1 can be attributed to the vibration of the H-O-H deformation of surface hydroxyl groups and water molecules adsorbed on the nanomaterial surface, which is characteristic of high surface hydroxyl group concentration for nanocrystalline ferrites. The broad band at 1123 cm⁻1 corresponds to the asymmetric metal-oxygen-metal (Fe-O-Fe and Pb-O-Fe) stretch vibrations with surface oxygen contribution. Further, in the low-wavenumber region below 900 cm⁻1, several distinct absorption bands are observed. A band in the range of 820–860 cm⁻1 corresponds to Fe–O–Fe bending vibrations within the interconnected metal–oxygen polyhedra. Two closely spaced bands between 680 and 720 cm⁻1 are attributed to Pb–O stretching and Fe–O stretching in distorted octahedral sites, arising from non-equivalent bonding environments of Ca2⁺, Pb2⁺, and Fe3⁺ ions in the lattice. Additional bands at 580–600 cm⁻1 and 520–540 cm⁻1 are associated with Fe–O stretching vibrations in octahedral and tetrahedral sites, respectively, while bands in the 400–450 cm⁻1 region are assigned to lattice vibrations involving Ca–O and Pb–O bonds.

In the CoO/CaPbFe₂O₄-NH, all characteristic bands of CaPbFe₂O₄ are preserved, indicating the retention of the parent ferrite structure. Slight shifts and broadening of the metal–oxygen vibrations suggest lattice distortion and strong interfacial interactions induced by CoO incorporation. An additional band observed at 470–490 cm⁻1 corresponds to Co–O stretching vibrations, confirming successful incorporation of CoO into the nanohybrid structure.

Scanning electron microscopy (SEM) analysis was performed to characterize the surface morphology of synthesized CaPbFe₂O₄-NPs, as seen in the micrograph (Figure 1c). The SEM micrograph shows that the synthesized nanoparticles are irregularly shaped, with a predominance of granular and quasi-polyhedral morphologies. These nanoparticles are observed to be of non-uniform size and randomly dispersed. Yet, there are clear signs of agglomeration, a common occurrence for ferrite-based nanoparticles due to their high surface energy and magnetism. However, individual nanoparticles are still visible even in the aggregates, thus demonstrating that the primary nanoparticles are indeed on the nanometer scale. Based on the scale bar (500 nm) and estimates, the size of the synthesized nanoparticles ranges from 80 to 200 nm; however, larger aggregates are present due to particle agglomeration. Furthermore, the surface of the synthesized nanoparticles appears highly uneven and rough, which might enhance certain surface characteristics, such as adsorption or electrochemical activity. Furthermore, the synthesis of CoO to CaPbFe₂O₄–NPs leads to increased roughness of the synthesized product (CoO/CaPbFe₂O₄–NH), as depicted in Figure 1(d).

The elemental composition and phase formation of the synthesized samples were investigated using energy-dispersive X-ray (EDX) spectroscopy. Figure S1(a) presents the EDX spectrum of the pristine CaPbFe₂O₄ sample. The spectrum clearly shows the presence of Ca, Pb, Fe, and O, with no extraneous elemental peaks, confirming the successful formation and high purity of CaPbFe₂O₄. The corresponding weight percentages are O (35.2%), Pb (33.4%), Ca (20.5%), and Fe (11.0%), which are in good agreement with the expected stoichiometric composition of CaPbFe₂O₄. The relatively high oxygen content further confirms the oxide nature of the compound. These results indicate that Ca and Pb are effectively incorporated into the iron oxide lattice, resulting in a single-phase mixed-metal oxide system. Figure S1(b) shows the EDX spectrum of the CoO/CaPbFe₂O₄ composite. In addition to the characteristic peaks of Ca, Pb, Fe, and O, a distinct Co peak is observed, confirming the successful incorporation of CoO into the CaPbFe₂O₄ matrix. The elemental weight percentages are Fe (72.1%), O (23.4%), Pb (2.8%), Ca (0.9%), and Co (0.8%). The dominance of Fe and O indicates that CaPbFe₂O₄ remains the primary host phase, while the presence of Co in a smaller proportion suggests that CoO is well dispersed, likely on the surface or at the grain boundaries of CaPbFe₂O₄. The reduced Ca and Pb contents compared to the pristine sample further support the formation of a hetero-structured CoO/CaPbFe₂O₄ composite rather than a bulk Co-substituted phase. The EDX analysis confirms the phase purity of CaPbFe₂O₄-NPs and the successful formation of the CoO/CaPbFe₂O₄-NH, with no evidence of unwanted impurities. These findings are consistent with the structural and morphological results and validate the effective synthesis strategy employed in this study.

Supplementary materials

The surface morphology and particle size distribution of the CoO/CaPbFe₂O₄ composite were examined using atomic force microscopy (AFM), as shown in Figure S2(a). The two-dimensional AFM topographical image reveals a densely packed granular surface with well-distributed nanostructures over the scanned area of approximately 0.5 × 0.5 µm2. The surface exhibits noticeable height variations, indicating the formation of nanoscale grains with partial agglomeration, which is commonly observed in oxide-based nanocomposites due to high surface energy. The corresponding height profile indicates that the surface roughness arises from closely packed nanoparticles with non-uniform grain boundaries. The color contrast in the AFM image reflects height variations ranging from low-lying regions to prominent protrusions, suggesting effective surface coverage and the formation of a textured morphology. Such surface features are beneficial for enhancing interfacial contact and surface-related properties.

The particle-size distribution histogram derived from the AFM data shows that the grain sizes are predominantly in the nanometer range (Figure S2b). The average particle size is estimated to be ∼34.6 nm with a range of 5.0 to 90.3 nm, confirming the nanocrystalline nature of the CoO/CaPbFe₂O₄-NH [27]. The relatively narrow size distribution indicates good control over particle growth during synthesis. At the same time, the presence of slightly larger grains may be attributed to localized agglomeration of CoO on the CaPbFe₂O₄ surface.

3.2. Electrochemical characterization of CoO/CaPbFe2O₄-NH/GCE

The electrochemical oxidation/reduction characteristics of the bare GCE, CaPbFe₂O₄/GCE, and modified CoO/CaPbFe₂O₄-NH/GCE were investigated. The CoO/CaPbFe₂O₄-NH/GCE exhibited a higher current than the bare GCE and CaPbFe₂O₄/GCE (Figure S3a). Modified CoO/CaPbFe₂O₄-NH/GCE was selected for further investigation. Likewise, the modified CoO/CaPbFe₂O₄-NH/GCE was characterized for its electron-transfer behavior using CV measurements (Figure S3b). It was found that the potential difference between the cathodic and anodic peaks decreases at high current intensity, indicating an excellent electron-transfer rate due to the electrode’s large surface area. The redox current increased with increasing scan rate in the range of 10 to 90 mV s-1, indicating direct proportionality to the square root of the scan rate (Figure S3c). Additionally, the electroactive surface area of bare GCE, CaPbFe₂O₄/GCE, and CoO/CaPbFe₂O₄-NH/GCE was calculated using the Randles-Sevick equation [27]. The electroactive surface area was determined to be 0.0451, 0.137, and 0.263 cm2 for bare GCE, CaPbFe₂O₄/GCE, and CoO/CaPbFe₂O₄-NH/GCE. The higher surface area of CoO/CaPbFe₂O₄-NH/GCE as compared to GCE and CaPbFe₂O₄/GCE makes it an important substrate for efficient electrochemical sensing.

3.3. Simultaneous electrochemical detection of CFO and LZD

The electrochemical oxidation and reduction current responses of 100 µM CFO and LZD, respectively, were studied at CoO/CaPbFe₂O₄-NH/GCE in 0.1 M BRB using the developed method. The electron transfer behavior of the modified CoO/CaPbFe₂O₄-NH/GCE was also evaluated by the CV (Figure S4a). A smaller difference was observed between the cathodic and anodic peak potentials at higher current intensities, indicating a superior rate of electron transfer associated with the electrode’s larger active surface area. With the increase in scan rate from 100 to 900 mV/s, a proportionality between redox current and the square root of the scan rate is observed, indicating a diffusion-controlled process for the electrode (Figure S4b).

The optimization of voltammetric modes was carried out by analyzing 100 µM of CFO and LZD in BRB, using the developed CoO/CaPbFe₂O₄-NH/GCE/DPV method. The study outcomes, as shown in Figure 2(a), indicated that the maximum current response was observed at pH 9.0 with BRB. So, a BR electrolyte at pH 9.0 is selected as the optimal pH for detecting CFO and LZD using the developed CoO/CaPbFe₂O₄-NH/GCE/DPV method.

(a) Optimization of mode study and (b) Electrolyte study of 100 µM CFO and LZD using the developed CoO/CaPbFe₂O₄-NH/GCE/DPV method.
Figure 2. (a) Optimization of mode study and (b) Electrolyte study of 100 µM CFO and LZD using the developed CoO/CaPbFe₂O₄-NH/GCE/DPV method.

For further optimization of the electrolyte, analysis of 100 µM CFO and LZD in BRB, phosphate, and acetate was done using the proposed CoO/CaPbFe₂O₄-NH/GCE/DPV technique. Based on the results of this experiment, shown in Figure 2(b), the highest peak current was recorded in BRB. Therefore, the BR electrolyte was considered the most suitable electrolyte for the determination of CFO and LZD using the proposed CoO/CaPbFe₂O₄-NH/GCE/DPV method. DPV response of CFO and LZD was studied at bare GCE, CaPbFe₂O₄/GCE, and modified CoO/CaPbFe₂O₄-NH/GCE. The CoO/CaPbFe₂O₄-NH/GCE exhibited a higher current response for both CFO and LZD than the bare GCE and CaPbFe₂O₄/GCE (Figure S5).

The pH of the solution plays a crucial role in determining the electrocatalytic behavior of the sensor. The electrochemical responses of CFO and LZD were investigated over a pH range of 4.0 to 10.0 using a BR electrolyte under identical experimental conditions. The DPV results (Figure 3a) revealed a gradual variation in peak current with changing pH, indicating that proton involvement influences the electrochemical process. As the pH increased from 4.0 to 9.0, the peak current for both analytes increased significantly, suggesting enhanced electron transfer kinetics and favorable interaction at the electrode surface. However, beyond pH 9.0, a decline in peak current was observed, which may be attributed to reduced proton availability and decreased electrochemical activity. Based on these observations, pH 9.0 was identified as the optimal condition, as it provided the maximum peak current and best analytical performance for the simultaneous detection of CFO and LZD. Furthermore, the relationship between peak potential (Ep) and pH was examined (Figure 3b), yielding a strong linear correlation. The regression equations were found to be: CFO, y = −0.0154x + 0.7696 (R2 = 0.9721), and LZD, y = −0.0656x + 0.4845 (R2 = 0.9884), confirming the involvement of protons in the electrochemical reaction process.

(a) Optimization of pH and (b) Linear relationship between varying pH and potential in 0.1 M BRB for the detection of 100 µM CFO and LZD using the developed CoO/CaPbFe₂O₄-NH/GCE/DPV method.
Figure 3. (a) Optimization of pH and (b) Linear relationship between varying pH and potential in 0.1 M BRB for the detection of 100 µM CFO and LZD using the developed CoO/CaPbFe₂O₄-NH/GCE/DPV method.

The linear shift in peak potential (Ep) with pH indicates the involvement of protons in the electrochemical reaction process. According to the Nernst equation, a theoretical slope of approximately 59 mV/pH suggests an equal number of electrons and protons participating in the reaction. In the present study, the slope value obtained for LZD (−0.0656 V/pH ≈ −65.6 mV/pH) is close to the theoretical value, indicating that the oxidation of LZD involves an equal number of electrons and protons. However, the slope value for CFO (−0.0154 V/pH ≈ −15.4 mV/pH) is much lower than the theoretical value, suggesting that the oxidation mechanism of CFO is predominantly governed by electron transfer. These results confirm that distinct electrochemical mechanisms underlie the oxidation of CFO and LZD at the modified electrode surface.

3.4. Analytical performance of CoO/CaPbFe₂O₄-NH/GCE for electrochemical detection of CFO and LZD

The calibration plot was drawn between the currents and the concentrations of CFO and LZD in the range of 0.05– 500 µM and 0.08– 350 µM, with the regression equations of I (µA) = 0.03 × CFO + 4.38 and I (µA) = 0.0195 × LZD + 2.89, respectively. The coefficient of determination (R2) from the calibration plot indicates strong linearity, with values of 0.997 and 0.991 (Figures 4a and b). Separate DPV calibrations for CFO and LZD were also studied at CoO/CaPbFe₂O₄-NH/GCE (Figures S6 and S7). This was determined using 3σ/slope and 10σ/slope, respectively, where σ is the standard deviation of the calibration curve [28]. The limits of detection (LOD) and limit of quantification (LOQ) of CFO were determined to be 0.0017 and 0.0051 µM, respectively. The LOD and LOQ of LZD were determined to be 0.0052 and 0.0157 µM, respectively. The reduction and oxidation peak currents (n = 8) of 100 µM CFO and LZD, respectively, using DPV were employed to study the stability of CoO/CaPbFe₂O₄-NH/GCE. The results in Figure S8 indicated the high stability of CoO/CaPbFe₂O₄-NH/GCE, with % relative standard deviation (RSD) < 2.0 between the peak currents for the electrochemical detection of CFO and LZD. Furthermore, the electrode was stored for 25 days, and tests of the 100 µM CFO and LZD were carried out every 5 days to assess repeatability across days (Figure S9). Before and after the electrode application, it was washed with deionized water and stored at 4°C. The peak current retention rate of CoO/CaPbFe₂O₄-NH/GCE was around 95%, indicating a respectable level of consistency. These findings demonstrate the consistency and reliability of CoO/CaPbFe₂O₄-NH/GCE across repeated use, making it more appropriate for long-term applications. To test the reproducibility of the CoO/CaPbFe₂O₄-NH/GCE fabrication process, however, three CoO/CaPbFe₂O₄-NH/GCE were fabricated. The remarkable reproducibility of the recently developed approach was illustrated by the observation that the current response of 100 µM CFO and LZD on these three produced CoO/CaPbFe₂O₄-NH/GCEs was remarkably comparable to one another (% RSD < 5.0) (Figure S10).

(a) Calibration, (b) Linear relationship of current vs concentration analysis using CoO/CaPbFe₂O₄-NH/GCE/DPV.
Figure 4. (a) Calibration, (b) Linear relationship of current vs concentration analysis using CoO/CaPbFe₂O₄-NH/GCE/DPV.

The analytical results of the voltammetric method currently developed (CoO/CaPbFe₂O₄-NH/GCE/DPV) were compared with those of prior research. The proposed electrochemical sensor (CoO/CaPbFe₂O₄-NH/GCE) is compared with the literature-reported analytical methods for detecting CFO and LZD. The proposed electrochemical sensor is superior to the reported studies, as evidenced by its wide calibration range and significantly lower detection limit, as illustrated in Table 1 [29-34]. The CoO/CaPbFe₂O₄-NH/GCE increases electron transfer efficiency due to its catalytic activity towards CFO and LZD; hence, the electron transfer resistance is decreased.

Table 1. Comparative study of the developed CoO/CaPbFe₂O₄-NH/GCE/DPV method with reported studies for the detection of CFO and LZD.
Material Technique Dynamic range (µM)
LOD (µM)
References
CFO LZD CFO LZD
Ab-25OHD/SPE/FMTAD SPR 13.0 – 130 - 2.6 - [29]
CYP27B1/GCE CV 0.013 – 0.52 - - - [30]
BSA/Anti-VD/Fe3O4-PANnFs/ITO DPV 0.026 – 0.26 - 0.0003 - [31]
ERGO-BEN/GCE DPV - - - 0.1 [32]
BDDE SWV - - - 0.15 [33]
PoDA@CaO-NPs/CPE DPV - - - 0.00127 [34]
CoO/CaPbFe₂O₄-NH/GCE DPV 0.05 – 500 0.08 – 350 0.0017 0.0052 Current study

3.5. Interference study

The experiments were conducted to assess the reliability of the CoO/CaPbFe₂O₄-NH/GCE for precise detection, target analyte determination, and differentiation from potential interfering substances. Using DPV, a variety of interfering substances were examined at concentrations 100 times higher than the analyte (CFO and LZD), including levofloxacin, ciprofloxacin, mefenamic acid, glucose, paracetamol, oxalic acid, cadmium (Cd2⁺), lead (Pb2⁺), magnesium (Mg2⁺), and sodium (Na⁺) (Figure S11). Research reveals that a small number of selected species have little interference with CoO/CaPbFe₂O₄-NH/GCE, with a percentage RSD of 1.78%. In addition, the recovery rate was evaluated to assess the method’s accuracy in the presence of interfering species. The recovery (%) was calculated as the ratio of the detected concentration to the known added concentration of the analyte. The recovery values close to 100% indicate that interfering substances have a negligible influence on the detection of CFO and LZD, confirming the excellent selectivity and reliability of the proposed sensor. This suggests that CoO/CaPbFe₂O₄-NH/GCE performs very well for CFO and LZD sensing across various sample media (Table 2). The scheme illustration for sensing mechanism of CFO and LZD at CoO/CaPbFe2O4-NH/GCE is given in Figure S12.

Table 2. Interference study of numerous species for the detection of 100 µM CFO and LZD by CoO/CaPbFe₂O₄-NH/GCE.
Interfering species Recovery (%) RSD (%)
Levofloxacin 96.2 0.97
Ciprofloxacin 95.4 1.65
Mefenamic acid 97.6 1.64
Glucose 96.6 1.62
Paracetamol 98.5 0.97
Oxalic acid 97.2 0.95
Cd2+ 95.4 1.87
Pb2+ 97.7 1.95
Mg2+ 97.8 1.77
Na+ 97.6 1.87

3.6. Real sample study

The proposed method, based on CoO/CaPbFe₂O₄-NH/GCE with differential pulse voltammetry analysis (CoO/CaPbFe₂O₄-NH/GCE/DPV), was used to analyze CFO and LZD in wastewater samples (Table 3). CFO and LZD were identified below the detection limit (BDL) in wastewater samples. The developed CoO/CaPbFe₂O₄-NH/GCE/DPV method has been proven to be highly reliable for the detection of CFO and LZD through the standard addition method. The industrial effluents were tested with the spiked concentrations of CFO and LZD (10, 50, and 100 µM). The concentrations were measured, and the values were obtained. The measured concentration range of CFO and LZD was found to be 95.9-101.7%, with a percentage RSD less than 2.0%.

Table 3. Determination and validation of CFO and LZD in wastewater (n = 3) using CoO/CaPbFe₂O₄-NH/GCE.
Analyte Added (µM) Conc. (µM) Recovery (%) RSD (%)
Cholecalciferol 0 BDL -- --
10 9.76±0.15 96.1 – 99.1 1.53
50 48.8±0.26 97.28 – 98.32 0.53
100 99.94±0.38 99.56 – 100.32 0.38
Linezolid 0 BDL -- --
10 9.88±0.29 95.9 – 101.7 2.93
50 49.6±0.21 98.78 – 99.62 0.42
100 99.92±0.25 99.67 – 100.17 0.25

4. Conclusions

In this study, a novel cobalt oxide–doped calcium–lead ferrite nanohybrid (CoO/CaPbFe₂O₄-NH) was successfully synthesized via a green sol–gel approach and applied for electrochemical sensing. The fabricated CoO/CaPbFe₂O₄-NH/GCE demonstrated excellent electrocatalytic performance for the simultaneous detection of CFO and LZD, exhibiting well-defined oxidation peaks, a wide linear range, and low limits of detection (0.0095 µM for CFO and 0.024 µM for LZD). The enhanced sensing performance is attributed to the synergistic effects of CoO doping, increased active surface area, and improved electron transfer properties of the nanohybrid. Furthermore, the sensor showed good selectivity, repeatability, and stability, indicating its suitability for practical applications in complex sample matrices. These findings highlight the potential of CoO/CaPbFe₂O₄-NH as an efficient and reliable sensing platform for pharmaceutical analysis. In future work, the developed sensor can be extended to real-sample analysis in biological fluids and environmental matrices, and further optimized through surface functionalization or integration with advanced nanomaterials to enhance sensitivity and selectivity.

Acknowledgment

This work was supported by the Imam Mohammad Ibn Saud Islamic University (IMSIU).

CRediT authorship contribution statement

The current study is a result of the visionary work of Dr. Jameel Ahmed Baig, Dr. Imam Bakhsh Solangi, and Dr. Huma Shaikh, who provided their contribution as supervision, project management, review, and editing. Mr. Latif Ullah Khan, Dr. Sajjad Hussain, Dr. Faisal K. Algethami, and Dr. Nadeem Raza provided their assistance for the characterization of material, interpretation, and evaluation. A committed Ph.D. student, Ms. Iram Gul played a pivotal role in the creation of the original draft, its formal analysis, data curation, and methodology. Ph.D. candidate Saima Perveen expertly managed the technical parts, which included software use, research, and visualization.

Declaration of competing interests

There are no conflicts of interest.

Data availability

Access to the data assisting with the current research project can be granted upon formal request.

Declaration of generative AI and AI-assisted technologies in the writing process

The authors confirm that there was no use of artificial intelligence (AI)-assisted Technology for assisting in the writing or editing of the manuscript, and no images were manipulated using AI.

Supplementary data

Supplementary material to this article can be found online at https://dx.doi.org/10.25259/AJC_517_2026.

References

  1. . Impact of pharmaceutical contaminants in the environment. In: Environmental Contaminants. New York: Apple Academic Press; p. :167-202. (Last accessed: 15 September 2026)
    [Google Scholar]
  2. , , . A review on effective removal of emerging contaminants from aquatic systems: Current trends and scope for further research. Journal of Hazardous Materials. 2021;409:124413. https://doi.org/10.1016/j.jhazmat.2020.124413
    [Google Scholar]
  3. . A cost-effective and sensitive voltammetric sensor for determination of baicalein in herbal medicine based on shuttle-shape α-Fe2O3 nanoparticle decorated multi-walled carbon nanotubes. Colloids and Surfaces A: Physicochemical and Engineering Aspects. 2025;717:136850. https://doi.org/10.1016/j.colsurfa.2025.136850
    [Google Scholar]
  4. . Sensors for the detection of pharmaceuticals in wastewater and natural waters. In: Encyclopedia of Green Chemistry. Elsevier; p. :529-537. (Last accessed: 15 September 2026) https://doi.org/10.1016/B978-0-443-15742-4.00043-0
    [Google Scholar]
  5. . An ultrasensitive 4-aminophenol electrochemical sensors based on zinc and nitrogen-doped γ-cyclodextrin composites. Microchemical Journal. 2024;197:109905. https://doi.org/10.1016/j.microc.2024.109905
    [Google Scholar]
  6. . Silver-cuprous oxide nanocomposites and nanohybrids-based electrochemical nanoplatform for ultrasensitive chloramphenicol detection: Influence of external and internal nano-heterojunctions. Electrochimica Acta. 2025;532:146472. https://doi.org/10.1016/j.electacta.2025.146472
    [Google Scholar]
  7. . An efficient voltammetric sensing platform for trace determination of norfloxacin based on nanoplate-like α-zirconium phosphate/carboxylated multiwalled carbon nanotube nanocomposites. Microchemical Journal. 2024;206:111451. https://doi.org/10.1016/j.microc.2024.111451
    [Google Scholar]
  8. . Showcasing advanced electrocatalytic behavior of layered double hydroxide wrapped on carbon nanotubes: Real-time monitoring of L-cysteine in biological matrices. Chemical Engineering Journal. 2022;440:135985. https://doi.org/10.1016/j.cej.2022.135985
    [Google Scholar]
  9. , . Synthesis and characterization of nanomaterials for application in cost-effective electrochemical devices. Sustainability. 2023;15:10891. https://doi.org/10.3390/su151410891
    [Google Scholar]
  10. , , , , , , , , , , , , . Machine learning system to monitor Hg2+ and sulfide using a polychromatic fluorescence-colorimetric paper sensor. ACS Applied Materials & Interfaces. 2023;15:9800-9812. https://doi.org/10.1021/acsami.2c16565
    [Google Scholar]
  11. . Redefining nanobiosensors in rapid detection of viral infections: Where are we now? Trends in Environmental Analytical Chemistry. 2025;46:e00263. https://doi.org/10.1016/j.teac.2025.e00263
    [Google Scholar]
  12. , , , , , , . Green synthesis of electroactive magnesium ferrite nanoparticles for the selective determination of mefenamic acid in blood, pharmaceutical products, and wastewater. Analytical Letters. 2025;58:2395-2410. https://doi.org/10.1080/00032719.2024.2413455
    [Google Scholar]
  13. . Advances in metal ion–mediated macromolecular drug delivery. International Journal of Pharmaceutics. 2026;689:126501. https://doi.org/10.1016/j.ijpharm.2025.126501
    [Google Scholar]
  14. . The effect of calcium perovskite and newly developed magnetic CaFe2O4/CaTiO3 perovskite nanocomposite on degradation of toxic dyes under UV–visible radiation. Journal of Cluster Science. 2022;33:2475-2487. https://doi.org/10.1007/s10876-021-02168-4
    [Google Scholar]
  15. , , , , . Ultrasound‐accelerated, concise, and highly efficient synthesis of 2‐oxazoline derivatives using heterogenous calcium ferrite nanoparticles and their Dft studies. Journal of Chemistry. 2021;2021:7375058. https://dx.doi.org/10.1155/2021/7375058
    [Google Scholar]
  16. , , . Electrochemical sensing of vitamin D3: A comparative use of glassy carbon and unmodified screen-printed carbon electrodes. Chemosensors. 2023;11:575. https://doi.org/10.3390/chemosensors11120575
    [Google Scholar]
  17. , , , , , . Enhancing the chloramphenicol sensing performance of Cu–MoS2 nanocomposite-based electrochemical nanosensors: roles of phase composition and copper loading amount. RSC Advances. 2021;11:30544-30559.
    [Google Scholar]
  18. . Sources of vitamin D for humans. International Journal for Vitamin and Nutrition Research. 2022;92:118-125. https://doi.org/10.1024/0300-9831/a000733
    [Google Scholar]
  19. , . Cholecalciferol or calcifediol in the management of vitamin D deficiency. Nutrients. 2020;12:1617. https://doi.org/10.3390/nu12061617
    [Google Scholar]
  20. , , , , , , , , , . Boosting the selective electrochemical signals for simultaneous determination of chloramphenicol and furazolidone in food samples by using ZnFe2O4-based sensing platform: Correlation between analyte molecular structure and electronic property of electrode materials. Journal of The Electrochemical Society. 2022;169:106517. https://doi.org/10.1149/1945-7111/ac9715
    [Google Scholar]
  21. . Novel designed electrochemical sensor for simultaneous determination of linezolid and meropenem pneumonia drugs. Journal of Electroanalytical Chemistry. 2021;902:115814. https://doi.org/10.1016/j.jelechem.2021.115814
    [Google Scholar]
  22. , , , . High prevalence of multi-drug resistant methicillin-resistant Staphylococcus aureus in tertiary egyptian hospitals. Journal of Infection in Developing Countries. 2022;16:795-806. https://doi.org/10.3855/jidc.15833
    [Google Scholar]
  23. , , , . Contemporary pharmacologic treatments of MRSA for hospitalized adults: Rationale for vancomycin versus non-vancomycin therapies as first line agents. Expert Review of Anti-Infective Therapy. 2023;21:1309-1325. https://doi.org/10.1080/14787210.2023.2275663
    [Google Scholar]
  24. , , , , , , , , , , . Efficacy and safety of vancomycin, linezolid, and ceftaroline in the treatment of methicillin-resistant Staphylococcus aureus (MRSA): A systematic review and meta-analysis. Cureus. 2025;17:e77949. https://doi.org/10.7759/cureus.77949
    [Google Scholar]
  25. . NiO load K2Fe4O7 enhanced photocatalytic hydrogen production and photo-generated carrier behavior. Journal of Alloys and Compounds. 2022;903:163864. https://doi.org/10.1016/j.jallcom.2022.163864
    [Google Scholar]
  26. . CoFe2O4@Co3O4 synergistic nanoarchitecture composite for enhanced supercapacitor performance. Journal of Materials Science: Materials in Electronics. 2025;36 https://doi.org/10.1007/s10854-025-14629-x
    [Google Scholar]
  27. . Novel fluoride selective voltammetric sensing method by amino phenylboronic acid-zirconium oxide nanoparticles modified gold electrode. Microchemical Journal. 2022;174:107073. https://doi.org/10.1016/j.microc.2021.107073
    [Google Scholar]
  28. , , , , , . Lanthanum doped copper ferrite as efficient Electrocatalyst for simultaneous detection of bentazone and diuron in vegetable samples. Food Chemistry. 2025;481:144066. https://doi.org/10.1016/j.foodchem.2025.144066
    [Google Scholar]
  29. , , , , , , . Several approaches for vitamin D determination by surface plasmon resonance and electrochemical affinity biosensors. Biosensors & Bioelectronics. 2013;40:350-355. https://doi.org/10.1016/j.bios.2012.07.077
    [Google Scholar]
  30. . Detection of 25-hydroxyvitamin D3 with an enzyme modified electrode. Journal of Biosensors & Bioelectronics. 2016;07 https://doi.org/10.4172/2155-6210.1000193
    [Google Scholar]
  31. , , . Electrochemical immunosensor based on magnetite nanoparticles incorporated electrospun polyacrylonitrile nanofibers for vitamin-D3 detection. Materials Science & Engineering. C, Materials for Biological Applications. 2018;93:145-156. https://doi.org/10.1016/j.msec.2018.07.036
    [Google Scholar]
  32. . Fabrification of electroreduced graphene oxide–bentonite sodium composite modified electrode and its sensing application for linezolid. Electrochimica Acta. 2014;133:49-56. https://doi.org/10.1016/j.electacta.2014.04.022
    [Google Scholar]
  33. . Electrochemical and analytical performance of cathodically pretreated boron-doped diamond electrode for the determination of oxazolidinone antibiotic linezolid in cationic surfactant media. Journal of Electroanalytical Chemistry. 2020;878:114681. https://doi.org/10.1016/j.jelechem.2020.114681
    [Google Scholar]
  34. . A novel low –cost and sensitive sensor for the voltammetric nano detection of linezolid antibiotic in real samples using carbon paste electrode modified with calcium oxide nanoparticle combined with electropolymerized D-alanine. BMC Chemistry. 2025;19:305. https://doi.org/10.1186/s13065-025-01663-3
    [Google Scholar]
Show Sections