5.2
Impact Factor
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Corrigendum
Current Issue
Editorial
Erratum
Full Length Article
Full lenth article
Letter to Editor
Original Article
Research article
Retraction
Retraction notice
Review
Review Article
SPECIAL ISSUE: ENVIRONMENTAL CHEMISTRY
5.3
Impact Factor
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Corrigendum
Current Issue
Editorial
Erratum
Full Length Article
Full lenth article
Letter to Editor
Original Article
Research article
Retraction
Retraction notice
Review
Review Article
SPECIAL ISSUE: ENVIRONMENTAL CHEMISTRY
View/Download PDF

Translate this page into:

Original article
12 (
7
); 1774-1782
doi:
10.1016/j.arabjc.2014.11.039

UHPLC-MS/MS assay using environment friendly organic solvents: A green approach for fast determination of quetiapine in rat plasma

Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
Bioavailability Laboratory, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia

⁎Address: Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh, PO BOX No. 2457, KSA 11451. Tel.: +966 14697565, +966 535667290 (mobile); fax: +966 14676220. muziqbal@gmail.com (Muzaffar Iqbal) muziqbal@ksu.edu.sa (Muzaffar Iqbal)

Disclaimer:
This article was originally published by Elsevier and was migrated to Scientific Scholar after the change of Publisher.

Peer review under responsibility of King Saud University.

Abstract

Reduction or elimination of traditional hazardous chemicals in chromatographic separation and sample preparation is comparatively safer and can be considered as a greener approach for the determination of analytes in biological matrices. A rapid and sensitive UHPLC-MS/MS assay for determination of quetiapine in rat plasma was developed and validated using environment friendly and low toxic organic solvents as organic modifier in mobile phase and sample preparation. Quetiapine and risperidone (internal standard) were separated on Acquity BEH™ C18 column (50 × 2.1 mm, i.d. 1.7 μm) using ethanol–water-formic acid (80:20:0.1, v/v/v) as mobile phase at a flow rate of 0.3 mL/min. Detection was performed on tandem mass spectrometer using positive electrospray ionization source by multiple reaction monitoring mode. The precursor to product ion transitions of m/z 384.13 > 253.00 for quetiapine and m/z 411.18 > 191.07 for IS was used to quantify them respectively. The method was found to be linear in the concentration range of 0.45–500 ng/mL. All validation parameters were within acceptable range, as defined by guidelines of bio-analytical method validation. In conclusion, bioanalytical assay using UHPLC-MS/MS together with environment friendly and low toxic organic solvents in mobile phase and sample preparation may be considered as greener approach for quantification of analytes in plasma samples.

Keywords

Bioanalysis
Green
Tandem mass spectroscopy
Ultra-high performance liquid chromatography
Quetiapine
Pharmacokinetics
1

1 Introduction

Solvents, commonly used in analytical methodologies, are mostly volatile organic compounds that are hazardous to our environments. They lead to air pollution, are flammable in nature and can cause toxicity and/or carcinogenicity (Salvador Garrigues and de la Guardia, 2010). Green analytical chemistry is a modern era technique that involves methods to reduce or eliminate the use of the hazardous solvents, reagents, preservative and other chemicals that are harmful to human health or environment without compromising the performance and quality of analysis (Keith et al., 2007; Namieśnik, 2001). In the recent years, rapid rise in development of green analytical methods has been observed that has results to extensive research and high rate of publications in this area (Agnieszka Gałuszka and Namieśnik, 2013; Christopher J. Welch et al., 2010; Haq et al., 2017; Armenta et al., 2008; Tache et al., 2013; Tobiszewski et al., 2010; Vaher and Kaljurand, 2012).

Recently, few attempts have also been explored in literature for the use of environment friendly approach in bioanalytical technique (Bojko and Pawliszyn, 2012; Fountain, 2012; Ghosh, 2012; Heudi, 2012; Kaljurand and Koel, 2012; Rainville et al., 2012; Tsai et al., 2012). Green approach in bioanalytical methods can be implemented during chromatographic separation and sample preparation. Conventional HPLC mobile phase techniques (which use acetonitrile and/or methanol) are replaced with environment friendly alternatives such as water, ethanol, isopropanol or propyl carbonate (Rainville et al., 2012; Smith, 2008; Tache et al., 2013). Similarly, use of carbon dioxide in supercritical fluid chromatography (Dispas et al., 2012), reduction in consumption of solvents or additives through reduced column internal diameters (narrow or microbore ranges) and dimensions of packing (⩽2 μm) (Sandra et al., 2010; Zotou, 2012) adapted as the environment friendly approach in chromatographic separation. Additionally, selection of less harmful organic substitutes (e.g. ethyl acetate, 2-butanol) in liquid–liquid extraction (LLE), practices of liquid and solid phase micro-extraction (Abdel-Rehim and Abdel-Rehim, 2013; Farhadi et al., 2012; Kataoka, 2011; Kataoka and Saito, 2011) and sample reduction using dried blood sampling (Heudi, 2012) are becoming more popular methods and favorable choice in sample preparation.

Among the available analytical techniques; ultra-high performance liquid chromatography (UHPLC) has gained a considerable attention as both chromatographic separation and assay selectivity have been significantly improved using this technology (Liu et al., 2009). Use of Aquity BEH column in UHPLC, which not only increase the separation throughput and efficiency but also reduces the retention time and volume of solvent required during separation (Kumar et al., 2012; Li et al., 2008; Novakova et al., 2006). Considering all these above mentioned advantages, UHPLC may be useful for greener approaches in bioanalytical assay (Cielecka-Piontek et al., 2013).

Quetiapine (QUE), a dibenzothiazepine derivative is an atypical antipsychotic, indicated for the treatment of schizophrenia, acute mania in bipolar disorders, and bipolar depression in adults. It has also been found to be effective as a monotherapy and as an adjunctive to a mood stabilizer (Altamura et al., 2011; Chiesa et al., 2012; Dispas et al., 2012; Patteet et al., 2012; Vieta et al., 2010). Therapeutic drug monitoring is a common and an important requirement in antipsychotic treatment to control the compliance and avoidance of extrapyramidal side effects (Hiemke et al., 2004; Musenga et al., 2009). It is important to perform accurate monitoring of QUE levels in blood in order to reduce the side effects and to optimize treatment. In view of this, to date, innumerable assays have been reported for quantification of QUE (alone and in combination with other drugs) in biological matrices (e.g. plasma, serum, tissue, oral fluids and microsomes). These techniques include HPLC with UV detection (Davis et al., 1999; Frahnert et al., 2003; Hasselstrom and Linnet, 2003; Mandrioli et al., 2002; Mercolini et al., 2007; Sachse et al., 2006; Saracino et al., 2006) gas chromatography mass spectroscopy (GC MS) (da Fonseca et al., 2013; Langman et al., 2004; Pullen et al., 1992) liquid chromatography mass spectroscopy (Zhou et al., 2004), liquid chromatography tandem mass spectroscopy (LC-MS/MS) (Barrett et al., 2007; Davis et al., 2010; Fisher et al., 2012a,b; Kirchherr and Kuhn-Velten, 2006; Li et al., 2004; Lin et al., 2004; Nirogi et al., 2008; Ostad Haji et al., 2013; Pan et al., 2012; Xiong et al., 2013) and UHPLC-MS/MS (Amundsen et al., 2013; Ansermot et al., 2013; Ji-Ying Tu et al., 2008; Li et al., 2007; Patteet et al., 2013). Most of the above mentioned techniques are low sensitive as well as time consuming. Although, the previously reported LC-MS/MS and UHPLC-MS/MS methods were also sensitive, but the solvents used in chromatographic separation and sample preparation falls under the category of hazardous wastes which causes serious environment, health, and safety (EHS) concerns, including human and eco-toxicity issues (Cielecka-Piontek et al., 2013; Rainville et al., 2012; Salvador Garrigues and de la Guardia, 2010).

Despite of available possibilities for green bioanalytical approach, very meager information exists regarding its use. To the best of our knowledge, only one validated method is available in literature, which used the greener approach for bioanalysis throughout the study (Cheregi et al., 2013).

Therefore, the present study aimed to develop a generic UHPLC-MS/MS method using environment friendly and low toxic solvents, a green approach, which can facilitate the rapid determination of QUE in plasma samples.

2

2 Experimental

2.1

2.1 Chemicals and reagents

Quetiapine (purity ⩾ 98 %) and risperidone (internal standard; purity ⩾ 98%) were used as reference substance in this study. QUE was received as a gratis from Ranbaxy Laboratories India and risperidone was purchased from Sigma–Aldrich (St. Louis, MO), USA. Ethanol, ethyl acetate and methanol were of HPLC grade and were obtained from VWR International Ltd. UK. Formic acid and sodium hydroxide were of analytical grade and obtained from Qualikems Fine Chem. Pvt. Ltd., Vadodara India. All aqueous solutions used in this study were prepared by using Milli-Q water purified method using Milli-QR Gradient A10R (Millipore, Moscheim Cedex, France) with pore size 0.22 μm. Blank plasma was prepared in laboratory from drug free healthy rats which were obtained from the Animal Care and Use Centre, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia and was stored at −80 °C until used.

2.2

2.2 Calibration standards and quality control samples

Standard stock solutions (100 μg/mL) of QUE and risperidone (IS) were prepared in methanol and kept in the refrigerator at 4 °C for use within 15 days of preparation. Working solutions of QUE for calibration standards were prepared from stock solution using methanol:water (50:50, v/v). A 20 μL aliquot of each working solutions was added to 200 μL of blank rat plasma to obtain the final calibration standard between 0.45 and 500 ng/mL. Quality control (QC) samples at four different concentrations: 0.48, 1.5, 60 and 400 ng/mL in blank rat plasma were also prepared in a similar manner and treated as lower limit of quantification for QC (LLOQ QC), low QC (LQC), mid QC (MQC) and high QC (HQC) respectively. Spiked plasma calibration standards and quality control samples were kept at −80 °C until used during validation and/or analysis. The IS working solution (200 ng/mL) for routine use was prepared by diluting the risperidone stock solution in methanol:water (50:50, v/v) and was kept in the refrigerator at 4 °C.

2.3

2.3 UHPLC separation and MS/MS parameters

The equipment consisted of ACQUITY™ UHPLC system coupled to triple–quadruple tandem mass spectrometer Micromass® Quattro micro™ (Waters Corp., Milford, MA, USA). The UHPLC system included quaternary solvent manager, a binary pump, degasser, autosampler with an injection loop of 10 μL and a column heater–cooler. The chromatographic separation was performed on Acquity BEH™ C18 column (50 × 2.1 mm, i.d., 1.7 μm, Waters, USA) maintained at temperature of 40 ± 2 °C. The mobile phase composed of ethanol–water-formic acid (80:20:0.1, v/v/v) at a flow rate of 0.3 mL/min. The injection volume was 10 μL in partial loop mode and the temperature of the autosampler was 15 ± 2 °C.

Triple–quadruple tandem mass spectrometer equipped with electrospray ionization (ESI) interface was used for analytical detection. The detection was performed in ESI positive mode using multiple reaction monitoring (MRM) by the ion transitions of m/z 384.13 > 253.00 for QUE and m/z 411.18 > 191.07 for IS, having dwell time of 0.161 s. Nitrogen was used as a desolvating gas at a flow rate of 650 L/h. The desolvating temperature was 350 °C whereas source temperature was 150 °C. The collision gas (argon) flow was 0.1 mL/min and capillary voltage was set at 3.5 kV. The compound parameters such as cone voltage and collision energy were set at 40 V and 24 eV for QUE and 42 V and 30 eV for IS respectively. The Mass Lynx software (Version 4.1, SCN 714) was used to control the UHPLC-MS/MS system. Data were collected and processed using TargetLynx™ program.

2.4

2.4 Sample preparation

Plasma samples stored at −80 °C were thawed at room temperature and vortexed for 30 s before sample preparation. In a clean 10 mL-glass tube, an aliquot of 200 μL of spiked calibration standards, QCs and unknown plasma samples were transferred and 10 μL of IS (200 ng/mL) was added in each tube except blank. The 50 μL of 0.1 M sodium hydroxide was added into each tube and vortexed for 30 s. Then, 2 mL of ethyl acetate was added into each tube and again vortexed gently for 3 min followed by centrifugation for 5 min at 4000g and 4 °C. After centrifugation, upper portion of the organic layer was transferred to a clean test tube, and evaporated to dryness under a stream of nitrogen at approximately 40 °C. The dried extracts were reconstituted in 200 μL of ethanol and transferred into HPLC vials for the analysis.

2.5

2.5 Method validation

The developed assay was fully validated in rat plasma according to guidelines of bioanalytical method validation set by the United States Food and Drug Administration and European Medicines Agency (EMA, 2011; FDA, 2001). The evaluated validation parameters included selectivity, linearity of response, accuracy, precision, matrix effects, recovery, dilution integrity and stability of analytes in both short-term sample processing and long-term storage.

Method selectivity was assessed by comparing the chromatograms of blank rat plasma samples with chromatograms of spiked plasma samples at LLOQ (0.45 ng/mL) and IS (20 ng/ml). The response of interferences in blank plasma was limited to ⩽20% of the response of analytes and ⩽5% of the IS. The linearity of the method was determined by plotting the plasma calibration curve in triplicate at eight different concentrations ranging from 0.45 to 500 ng/mL. The precision of the assay was expressed as percentage coefficient of variation (% CV) at four different concentrations whereas accuracy was expressed as a percentage of deviation from the respective nominal value. The intra-day and inter-day precision and accuracy were evaluated at four different QC concentration levels (LLOQ QC, LQC, MQC and HQC) in six replicate on the same day and on three different days, respectively. The recoveries of QUE at three QC levels were determined by comparing peak area ratios of plasma spiked with analyte prior to extraction with the peak area ratios of plasma spiked with analyte after the extraction. The matrix effects were determined by calculating the peak area ratio of extracted rat plasma postspiked with analyte to the peak area of the analyte in mobile phase in the same concentration. Deviation in analyte concentrations of a maximum of 15% was considered acceptable and in line with current EMEA guideline (EMA, 2011). The extraction recovery and matrix effects of IS were also evaluated using the same procedure.

The stability of QUE in rat plasma under different anticipated conditions was assessed by using six replicates of LQC and HQC. Bench-top stability was assessed after keeping the plasma samples to room temperature for ∼6 h, the freeze–thaw stability was determined after three cycles of freeze–thaw. Autosampler storage stability was determined by storing the reconstituted QC samples for ∼48 h under autosampler condition (maintained at 15 °C) before analysis. Long-term stability was assessed after storage of the test samples at around −80 °C for 60 days. The working solutions and stock solutions of QUE and the IS were also evaluated for their stability at room temperature for 12 h and at refrigerator temperature (below 10 °C) for 15 days. Dilution integrity exercise was carried out to ensure the integrity of analyte in those samples which were beyond upper limit of the standard curve and need to be diluted. A fresh stock of QUE was prepared and spiked in plasma to get a concentration level of 1.8 times of highest standard of the usual calibration standard, and then diluted 2 and 4 times with the same plasma. Six aliquots of both dilutions were processed along with freshly spiked calibration standards and analyzed by back calculation using regression equation obtained.

2.6

2.6 Application to pharmacokinetic interaction study in rats

To demonstrate the utility of this assay, method was applied to pharmacokinetic interaction study of QUE with green tea extracts (GTE) in rats. Twelve male wistar albino rats weighing from 180 to 220 g were randomly divided into two groups (6 in each). Experiments were carried out according to the guidelines of the animal care and use committee at King Saud University. Rats in treatment group received GTE (175 mg/kg, oral) for seven days, while control group received normal saline in same volume. Blood samples (approximately 0.5 mL) were collected from the retro-orbital plexus into heparinized microfuge tubes at 0, 0.25, 0.5, 1, 1.5, 2, 3, 4, 6, 8 and 12 h after administration of QUE (25 mg/kg, oral; suspended in 1% hydroxyl propyl methyl cellulose) in both groups. Plasma samples were harvested by centrifuging the blood at 5000g for 10 min and stored at −80 ± 10 °C until analysis.

3

3 Results

3.1

3.1 Method development

UHPLC-MS/MS operation parameters were carefully optimized before detection by tandem mass spectrometry using MRM of precursor–product ion transitions at m/z 384.13 > 253.0 for QUE and m/z 411.18 > 191.07 for IS. Initially the standard solution (200 ng/mL) of both QUE and IS was directly infused into the mass spectrometer for tuning in both positive and negative modes using ESI as the ionization source. It was observed that the signal intensity of positive ion (ESI+) was much higher than that of negative ion for both analyte and IS. Parameters, such as capillary and cone voltage, desolvation temperature, ESI source temperature and flow rate of desolvation gas and cone gas were optimized to obtain the optimum intensity of protonated molecular ions (M–H)+ of QUE and IS. Analyte produced the strongest product ion and daughter ion signals when cone voltage and collision energy were set at 40 V and 24 eV respectively. For IS, the optimized cone voltage and collision energy were 42 V and 30 eV respectively. The precursor and product ion spectra of QUE and IS are shown in Fig. 1.

Precursor and product ion spectra for quetiapine (A1 and A2) and IS (B1 and B2), respectively.
Figure 1 Precursor and product ion spectra for quetiapine (A1 and A2) and IS (B1 and B2), respectively.

Feasibility of different compositions of ethanol and isopropranol and water containing 0.1% formic acid as mobile phase were tried for separation of analyte and IS with altered flow-rates (in the range of 0.2–0.4 mL/min) on BEH™ C18 column (50 × 2.1 mm, i.d. 1.7 μm). The best peak resolution along with high sensitivity was achieved with an isocratic elution by a mobile phase comprising of ethanol–water-formic acid (80:20:0.1, v/v/v) at a flow-rate of 0.3 mL/min. The column oven temperature also optimized at 40 °C to adjust the back pressure which was finally set to approx. 8000 psi. The selected conditions were found to be suitable for the separation and determination of electrospray response for QUE and IS.

Clean samples are essential to minimize ion suppression and matrix effect in bioanalysis. Initially protein precipitation using ethanol and/or isopropranol was evaluated for sample preparation but the results were not satisfactory in terms of recovery and matrix effects. Finally, liquid-liquid extraction (LLE) using ethyl acetate, tertiary butyl ethyl ether and 2-butanol was tried as extracting solvents. Ethyl acetate produced better results compared to others. Extraction rate was also increased by alkalization of the compounds by adding 50 μL of 0.1 M sodium hydroxide before ethyl acetate. Effects of different extracting solvents (ethyl acetate, tertiary butyl ethyl ether and 2-butanol) on quetiapine recovery and matrix effects are shown in Fig. 2.

Extraction recovery and matrix effects (%Mean ± %CV) of different extracting solvents at MQC concentration of quetiapine in rat plasma (n = 3).
Figure 2 Extraction recovery and matrix effects (%Mean ± %CV) of different extracting solvents at MQC concentration of quetiapine in rat plasma (n = 3).

3.2

3.2 Method validation

3.2.1

3.2.1 Selectivity

No significant peaks in blank plasma samples were detected at the corresponding retention time of analyte and IS. Representative MRM chromatograms of analyte and IS for blank plasma (showing no significant interference at the retention time of analyte and IS) as well as plasma spiked at LLOQ level are shown in Fig. 3A and B, respectively.

Representative MRM chromatograms of quetiapine and IS in (A) blank plasma; (B) plasma spiked at LLOQ level and (C) at one hour after oral administration of QUE 25 mg/kg in rat.
Figure 3 Representative MRM chromatograms of quetiapine and IS in (A) blank plasma; (B) plasma spiked at LLOQ level and (C) at one hour after oral administration of QUE 25 mg/kg in rat.

3.2.2

3.2.2 Linearity and lower limit of quantification

The linearity of the method was determined by a weighted (1/X2) least square regression analysis of standard plot associated with eight-point standard curve. The calibration curves were generated by plotting area ratio (analyte/IS) as a function of QUE concentration. The method was found to be linear in range between 0.45 and 500 ng/mL for QUE in rat plasma and LLOQ for this assay was 0.45 ng/mL. The determination coefficients (r2) were found to be consistently ⩾0.997 during the course of validation.

3.2.3

3.2.3 Precision and accuracy

The precision and accuracy data for QC samples (both inter-day and intra-day) are listed in Table 1. The intra-day and inter-day precision results were 3.8–11.3% and 4.5–9.1%, respectively; whereas the intra-day and inter-day accuracies were 91.1–112% and 94.5–112%, respectively. The accuracy was required to be limited to within ±15% (20% for LOQ QC) and precision was not to exceed ±15% (20% for LOQ QC.)

Table 1 Intra-day and inter-day precision and accuracy of QUE in rat plasma.
Nominal concentration (ng/mL) Run Mean ± SD (ng/mL) Precision (CV%) Accuracy (%)
Intra-day variation (six replicate at each concentration)
0.48 1 0.54 ± 0.03 5.5 112
2 0.53 ± 0.06 11.3 110
3 0.53 ± 0.05 9.4 111
1.50 1 1.56 ± 0.11 7.0 104
2 1.58 ± 0.13 8.2 105
3 1.55 ± 0.06 3.8 103
60.0 1 57.3 ± 4.42 7.7 95.4
2 61.7 ± 5.70 9.2 103
3 62.8 ± 5.68 9.0 105
400 1 364 ± 20.3 5.5 91.1
2 393 ± 37.0 9.4 98.1
3 378 ± 16.2 4.3 94.4
Inter-day variation (18 replicate at each concentration)
0.48 0.54 ± 0.04 7.4 112
1.50 1.57 ± 0.07 4.5 105
60.0 60.6 ± 5.56 9.1 101
400 378 ± 27.2 7.1 94.5

3.2.4

3.2.4 Recovery and matrix effects

The percentage recoveries (mean ± SD) of QUE obtained from plasma at three different QC concentrations level (1.50, 60 and 400 ng/mL) were 76.9%, 73.9% and 71.4% respectively. Mean recovery for the risperidone (IS) at the concentration employed was 67.3% (Table 2). These results indicate that the extraction efficiency for QUE using LLE method was satisfactory, consistent and concentration independent. The ion suppression effects were within ⩽15% and its relative standard deviation (%CV) was within ±5% among all QC concentration, indicated no relative matrix effects (Table 2).

Table 2 Extraction recovery and matrix effect (three QC samples) in rat plasma (n = 6).
Compound Nominal concentration (ng/mL) Extraction recovery Matrix effects
%Mean ± SD CV% %Mean ± SD CV%
Quetiapine 1.50 76.9 ± 5.8 7.6 89.8 ± 3.7 4.1
60.0 73.9 ± 8.0 10.8 87.2 ± 2.5 2.9
400 71.4 ± 4.9 6.9 86.7 ± 3.8 4.4
Mean 74.1 ± 2.7 3.7 87.9 ± 1.6 1.9
IS 20.0 67.3 ± 3.6 5.4 80.7 ± 3.2 4.0

3.2.5

3.2.5 Stability and dilution integrity

The stability and dilution integrity results are summarized in Table 3. These indicate that QUE spiked in rat plasma was stable for at least 6.0 h at room temperature, 48 h in autosampler, 60 days at around −80 °C and during three cycle of freeze–thaw when stored at around −80 °C. The stock solutions and working standard of QUE and IS were also stable for 15 days at refrigerator temperature (below 10 °C) and for 12 h at room temperature. In dilution integrity study, the percentage accuracy of two and four times diluted samples was to 96.3% and 97.0% of the nominal concentration for QUE. These results indicated that the dilution of the concentrated plasma sample up to four times maintains legibility and integrity of QUE concentration.

Table 3 Stability and dilution integrity data of QUE in rat plasma.
Stability Nominal concentration (ng/mL) (n = 6) Mean ± SD (ng/mL) Precision (CV %) Accuracy (%)
Bench top (6 h) 1.50 1.60 ± 0.06 3.7 106
400 374 ± 15.0 4.0 93.5
Freeze thaw (3 cycle) 1.50 1.55 ± 0.10 6.5 104
400 372 ± 25.0 6.0 93.0
In injector (48 h) 1.50 1.63 ± 0.06 3.5 108
400 428 ± 11.37 2.7 107
60 days at −80 °C 1.50 1.43 ± 0.13 8.8 95.0
400 365 ± 29.12 7.9 91.2
Dilution integrity 225 218.2 ± 12.9 5.9 97.0
450 433.0 ± 12.2 2.8 96.3

3.3

3.3 Pharmacokinetic interaction study in rats

The applicability of this validated method was demonstrated successfully in a pharmacokinetic interaction study of QUE with GTE. Representative MRM chromatogram of analyte and IS after one hour administration of QUE alone in rat are shown in Fig. 3C. The mean plasma concentration verses time profile of QUE is shown in Fig. 4.

Mean ± SEM plasma concentration-time curves of QUE after a single oral dose of 25 mg/kg with or without an oral dose of GTE 175 mg/kg.
Figure 4 Mean ± SEM plasma concentration-time curves of QUE after a single oral dose of 25 mg/kg with or without an oral dose of GTE 175 mg/kg.

4

4 Discussion

Binary mixture of water and polar organic solvents like methanol and acetonitrile comprise the majority of mobile phase utilized for liquid chromatography. These agents are used due to their miscibility with water, low viscosity, ability to produce good chromatographic peak shape and compatibility with UV and MS detection. Unfortunately, these solvents produce substantial hazards to the analysts during handling as well as produce harmful effects on the environment. In this study, the primary focus on the selection of the mobile phase was the replacement of these traditional (methanol and acetonitrile) solvents with non-traditional, less hazardous, environment friendly benign organic solvents. Non-traditional, alcoholic mobile phase; like, ethanol and isopropranol revealed promising results in replacing the traditional use of acetonitrile and methanol (Rainville et al., 2012). However, high viscosity of these two non-traditional solvents was the main challenge which could result in high back pressure during the process of separation. UHPLC chromatographic system is designed in a special way to withstand high system back-pressures, and the separation on it can be easily performed under very high pressures (up to 1000 psi), without any negative impact on analytical column or other components of chromatographic system (Novakova et al., 2006). In this study, the use of ethanol with the adjusted back pressure (approx. 8000 psi) and the column oven temperature (40 °C) was found to be suitable for the separation and determination of electrospray response for QUE and IS. Finally, mixture of ethanol–water-formic acid (80:20:0.1) was selected for chromatographic separation of quetiapine. Chromatographic separation of previously reported green bio-analytical assay (Cheregi et al., 2013) was based on mixture of propylene carbonate/ethanol in 7:3 ratio.

Commonly used sample preparation technique such as protein precipitation, LLE and solid phase extraction (SPE) generally consume substantial amount of organic solvents. Phospholipids present in plasma are considered as one of the most significant matrixes interferences encounter in protein preparation methodologies (Phillips and Dodge, 1967). But, due to ease and compatibility with mobile phase, sample extraction by protein precipitation using acetonitrile and/or methanol is often preferred over other solvents. However, both of them have been reported to less effective in the removal of the phospholipids compared to ethanol and isopropranol (Rainville et al., 2012). During this study, protein precipitation using ethanol and/or isopropranol in the presence or absence of acetic acid/formic acid was evaluated for sample preparation but the efforts resulted poor recoveries and sensitivity. LLE is one of the preferred sample preparation techniques during assay development that provides cleaner extracts than protein precipitation processes in most cases. LLE is more cost effective than SPE, especially when only non-halogenate extraction solvents such as hexanes and ethyl acetate are used. Tertiary butyl methyl ether, diethyl ether, dichloromethane, ethyl acetate, chloroform and n-hexane are commonly used as extracting solvents for liquid–liquid extraction. But here considering environment, health, and safety concerns (EHS); ethyl acetate, tertiary butyl ethyl ether and 2-butanol were tried as extracting solvents. Finally, ethyl acetate produced better result compared to others and was used as extracting agent in sample preparation. Liquid–liquid extraction is also employed in sample preparation of previous green bio-analytical assay (Cheregi et al., 2013), but 1-octanol was used as an extracting agent there followed by direct injection of large volume of the organic layer for analysis.

The developed UHPLC-MS/MS method using environment friendly organic solvents allow a fast and reliable determination of QUE plasma concentrations using 200 μl of plasma with a calibration range of 0.45–500 ng/mL and LLOQ 0.45 ng/mL. The method was successfully validated according to the current effective official guidelines for bioanalytical method validation and was successfully applied in a pharmacokinetic interaction study of QUE in rats. Since this assay was developed and validated in rat plasma samples, so it cannot be directly used for application in clinical samples or therapeutic drug monitoring. At least, partial validation in terms of precision and accuracy is necessary before application in human samples.

5

5 Conclusions

A green bioanalytical UHPLC-MS/MS method was developed and validated for the rapid determination of QUE in rat plasma using environment friendly and low toxic organic solvents. The developed method was successfully applied in pharmacokinetic study of QUE with GTE in rats. Replacement of traditional organic modifiers such as methanol or acetonitrile with ethanol did not produce any impact on peak symmetry and elution of both analyte and IS. Capacity of withstanding high back pressure (can handle the high viscosity characteristic of ethanol) along with AQUITY BEH column, 50 × 2.1 mm, i.d. 1.7 μm (leads to reduction of solvent required for separation and shortening of analysis time) enable UHPLC-MS/MS, the suitable equipment for green bioanalytical assay. Therefore, the present study shows the advantage of using less harmful solvents which protect environment from hazardous and polluting chemicals. Moreover, laboratory staffs are less exposed to toxic and corrosive organic solvents.

Acknowledgment

The author is thankful to the Deanship of Scientific Research and Research Center, College of Pharmacy, King Saud University.

References

  1. , , . Evaluation of microextraction by packed sorbent and micro-liquid chromatography-tandem mass spectrometry as a green approach in bioanalysis. Biomed. Chromatogr.. 2013;27:1225-1233.
    [Google Scholar]
  2. , , . The 12 principles of green analytical chemistry and the SIGNIFICANCE mnemonic of green analytical practices. Trends Anal. Chem.. 2013;50:78-84.
    [Google Scholar]
  3. , . Mood stabilizers for patients with bipolar disorder: the state of the art. Expert Rev. Neurother.. 2011;11:85-99.
    [Google Scholar]
  4. , . Quantitative determination of fifteen basic pharmaceuticals in ante- and post-mortem whole blood by high pH mobile phase reversed phase ultra high performance liquid chromatography-tandem mass spectrometry. J. Chromatogr. B. 2013;927:112-123.
    [Google Scholar]
  5. , . Fast quantification of ten psychotropic drugs and metabolites in human plasma by ultra-high performance liquid chromatography tandem mass spectrometry for therapeutic drug monitoring. J. Chromatogr. A. 2013;1292:160-172.
    [Google Scholar]
  6. , , , . Green analytical chemistry. TrAC Trends Anal. Chem.. 2008;27:497-511.
    [Google Scholar]
  7. , . Validated HPLC-MS/MS method for determination of quetiapine in human plasma. J. Pharm. Biomed. Anal.. 2007;44:498-505.
    [Google Scholar]
  8. , , . The benefits of using solid-phase microextraction as a greener sample preparation technique. Bioanalysis. 2012;4:1263-1265.
    [Google Scholar]
  9. , . Greener bioanalytical approach for LC/MS-MS assay of enalapril and enalaprilat in human plasma with total replacement of acetonitrile throughout all analytical stages. J. Chromatogr. B. 2013;927:124-132.
    [Google Scholar]
  10. , . Quetiapine for bipolar depression: a systematic review and meta-analysis. Int. Clin. Psychopharmacol.. 2012;27:76-90.
    [Google Scholar]
  11. , , , , , , , , , , . Greening analytical chemistry. Trends Anal. Chem.. 2010;29:667-680.
    [Google Scholar]
  12. , . UHPLC: the greening face of liquid chromatography. Chromatographia. 2013;76:1429-1437.
    [Google Scholar]
  13. , . Determination of seven selected antipsychotic drugs in human plasma using microextraction in packed sorbent and gas chromatography-tandem mass spectrometry. Anal. Bioanal. Chem.. 2013;405:3953-3963.
    [Google Scholar]
  14. , , , . Analysis and pharmacokinetics of quetiapine and two metabolites in human plasma using reversed-phase HPLC with ultraviolet and electrochemical detection. J. Pharm. Biomed. Anal.. 1999;20:271-282.
    [Google Scholar]
  15. , . Development and validation of an LC-MS/MS method for the determination of quetiapine and four related metabolites in human plasma. J. Pharm. Biomed. Anal.. 2010;51:1113-1119.
    [Google Scholar]
  16. , . Innovative green supercritical fluid chromatography development for the determination of polar compounds. J. Chromatogr. A. 2012;1256:253-260.
    [Google Scholar]
  17. EMA, 2011. Guideline for Bioanalytical Method Validation.
  18. , , , . Microextraction techniques in therapeutic drug monitoring. Biomed. Chromatogr.. 2012;26:972-989.
    [Google Scholar]
  19. FDA, U., 2001. Guideline for Bioanalytical Method Validation. Center for Drug Evaluation and Research.
  20. , . Plasma concentrations of quetiapine, N-desalkylquetiapine, o-desalkylquetiapine, 7-hydroxyquetiapine, and quetiapine sulfoxide in relation to quetiapine dose, formulation, and other factors. Ther. Drug Monit.. 2012;34:415-421.
    [Google Scholar]
  21. , . Measurement of quetiapine and four quetiapine metabolites in human plasma by LC-MS/MS. Biomed. Chromatogr.. 2012;26:1125-1132.
    [Google Scholar]
  22. , . Bioanalytical method development: considering information from a suite of complementary methods. Bioanalysis. 2012;4:115-119.
    [Google Scholar]
  23. , , , . Analysis of eighteen antidepressants, four atypical antipsychotics and active metabolites in serum by liquid chromatography: a simple tool for therapeutic drug monitoring. J. Chromatogr. B. 2003;794:35-47.
    [Google Scholar]
  24. , . Green bioanalysis: some innovative ideas towards green analytical techniques. Bioanalysis. 2012;4:1377-1391.
    [Google Scholar]
  25. Haq, N., et al., 2017. Applying green analytical chemistry for rapid analysis of drugs: adding health to pharmaceutical industry. Arab. J. Chem. 10, S777–S785.
  26. , , . Fully automated on-line quantification of quetiapine in human serum by solid phase extraction and liquid chromatography. J. Chromatogr. B. 2003;798:9-16.
    [Google Scholar]
  27. , . Green bioanalytical methods are now a reality. Bioanalysis. 2012;4:1257.
    [Google Scholar]
  28. , . Therapeutic monitoring of new antipsychotic drugs. Ther. Drug. Monit.. 2004;26:156-160.
    [Google Scholar]
  29. , , , . UPLC-MS–MS analysis of quetiapine and its two active metabolites, 7-Hydroxyquetiapine and 7-Hydroxy-N-dealkylquetiapine, in rat plasma and cerebrospinal fluid. Chromatographia. 2008;68:525-532.
    [Google Scholar]
  30. , , . Green bioanalytical chemistry. Bioanalysis. 2012;4:1271-1274.
    [Google Scholar]
  31. , . Current developments and future trends in solid-phase microextraction techniques for pharmaceutical and biomedical analyses. Anal. Sci.. 2011;27:893-905.
    [Google Scholar]
  32. , , . Recent advances in SPME techniques in biomedical analysis. J. Pharm. Biomed. Anal.. 2011;54:926-950.
    [Google Scholar]
  33. , , , . Green analytical methodologies. Chem. Rev.. 2007;107:2695-2708.
    [Google Scholar]
  34. , , . Quantitative determination of forty-eight antidepressants and antipsychotics in human serum by HPLC tandem mass spectrometry: a multi-level, single-sample approach. J. Chromatogr. B. 2006;843:100-113.
    [Google Scholar]
  35. , . UPLC: a preeminent technique in pharmaceutical analysis. Acta Pol. Pharm.. 2012;69:371-380.
    [Google Scholar]
  36. , , , . Fatal overdoses associated with quetiapine. J. Anal. Toxicol.. 2004;28:520-525.
    [Google Scholar]
  37. , . Simultaneous determination of quetiapine and three metabolites in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry. Acta Pharmacol. Sin.. 2004;25:110-114.
    [Google Scholar]
  38. , . Ultra-performance liquid chromatography-tandem mass spectrometry for the determination of atypical antipsychotics and some metabolites in in vitro samples. J. Chromatogr. B. 2007;850:581-585.
    [Google Scholar]
  39. , . A novel ‘peak parking’ strategy for ultra-performance liquid chromatography/tandem mass spectrometric detection for enhanced performance of bioanalytical assays. Rapid. Commun. Mass Spectrom.. 2008;22:486-494.
    [Google Scholar]
  40. , . A liquid chromatographic-electrospray-tandem mass spectrometric method for quantitation of quetiapine in human plasma and liver microsomes: application to study in vitro metabolism. J. Anal. Toxicol.. 2004;28:443-448.
    [Google Scholar]
  41. , . Strategy of accelerated method development for high-throughput bioanalytical assays using ultra high-performance liquid chromatography coupled with mass spectrometry. Anal. Chem.. 2009;81:9225-9232.
    [Google Scholar]
  42. , . HPLC analysis of the novel antipsychotic drug quetiapine in human plasma. J. Pharm. Biomed. Anal.. 2002;30:969-977.
    [Google Scholar]
  43. , . Simultaneous analysis of classical neuroleptics, atypical antipsychotics and their metabolites in human plasma. Anal. Bioanal. Chem.. 2007;388:235-243.
    [Google Scholar]
  44. , . Antipsychotic and antiepileptic drugs in bipolar disorder: the importance of therapeutic drug monitoring. Curr. Med. Chem.. 2009;16:1463-1481.
    [Google Scholar]
  45. , . Green analytical chemistry – some remarks. J. Sep. Sci.. 2001;24:151.
    [Google Scholar]
  46. , . Sensitive liquid chromatography tandem mass spectrometry method for the quantification of Quetiapine in plasma. Biomed. Chromatogr.. 2008;22:1043-1055.
    [Google Scholar]
  47. , , , . Advantages of application of UPLC in pharmaceutical analysis. Talanta. 2006;68:908-918.
    [Google Scholar]
  48. , . Quetiapine and norquetiapine serum concentrations and clinical effects in depressed patients under augmentation therapy with quetiapine. Ther. Drug. Monit.. 2013;35:539-545.
    [Google Scholar]
  49. , , , . Validated LC-MS–MS method for the determination of quetiapine in human plasma: application to a pharmacokinetic study. J. Chromatogr. Sci.. 2012;50:277-282.
    [Google Scholar]
  50. , . Therapeutic drug monitoring of common antipsychotics. Ther. Drug. Monit.. 2012;34:629-651.
    [Google Scholar]
  51. , . High throughput identification and quantification of 16 antipsychotics and 8 major metabolites in serum using ultra-high performance liquid chromatography-tandem mass spectrometry. Clin. Chim. Acta. 2013;429C:51-58.
    [Google Scholar]
  52. , , . Composition of phospholipids and of phospholipid fatty acids of human plasma. J. Lipid. Res.. 1967;8:676-681.
    [Google Scholar]
  53. , , , . Determination of an antipsychotic agent (ICI 204,636) and its 7-hydroxy metabolite in human plasma by high-performance liquid chromatography and gas chromatography-mass spectrometry. J. Chromatogr.. 1992;573:49-57.
    [Google Scholar]
  54. , . Investigation of microbore UPLC and nontraditional mobile phase compositions for bioanalytical LC-MS/MS. Bioanalysis. 2012;4:1287-1297.
    [Google Scholar]
  55. , . Automated analysis of quetiapine and other antipsychotic drugs in human blood by high performance-liquid chromatography with column-switching and spectrophotometric detection. J. Chromatogr. B. 2006;830:342-348.
    [Google Scholar]
  56. , , . Green strategies for decontamination of analytical wastes. Trends Anal. Chem.. 2010;29:592-601.
    [Google Scholar]
  57. , , , , , . Green chromatography (part 1): introduction and liquid chromatography. LC GC Eur.. 2010;23:242-259.
    [Google Scholar]
  58. , . Simultaneous determination of fluvoxamine isomers and quetiapine in human plasma by means of high-performance liquid chromatography. J. Chromatogr. B. 2006;843:227-233.
    [Google Scholar]
  59. , . Superheated water chromatography – a green technology for the future. J. Chromatogr. A. 2008;1184:441-455.
    [Google Scholar]
  60. , . Greening pharmaceutical applications of liquid chromatography through using propylene carbonate-ethanol mixtures instead of acetonitrile as organic modifier in the mobile phases. J. Pharm. Biomed. Anal.. 2013;75:230-238.
    [Google Scholar]
  61. , , , . Green analytical chemistry – theory and practice. Chem. Soc. Rev.. 2010;39:2869-2878.
    [Google Scholar]
  62. , , , . High-field asymmetric waveform ion mobility spectrometry with solvent vapor addition: a potential greener bioanalytical technique. Bioanalysis. 2012;4:1363-1375.
    [Google Scholar]
  63. , , . The development of paper microzone-based green analytical chemistry methods for determining the quality of wines. Anal. Bioanal. Chem.. 2012;404:627-633.
    [Google Scholar]
  64. , . Treatment options for bipolar depression: a systematic review of randomized, controlled trials. J. Clin. Psychopharmacol.. 2010;30:579-590.
    [Google Scholar]
  65. , , , . Development and validation of a sensitive and robust LC-MS/MS with electrospray ionization method for simultaneous quantitation of quetiapine and its active metabolite norquetiapine in human plasma. Clin. Chim. Acta. 2013;423:69-74.
    [Google Scholar]
  66. , . Simultaneous determination of clozapine, olanzapine, risperidone and quetiapine in plasma by high-performance liquid chromatography–electrospray ionization mass spectrometry. J. Chromatogr. B. 2004;802:257-262.
    [Google Scholar]
  67. , . An overview of recent advances in HPLC instrumentation. Central Eur. J. Chem.. 2012;10:554-569.
    [Google Scholar]
Show Sections